100002043

1. Modify the first paragraph in Option 2. Air Testing so it reads: "Conduct baseline IAQ testing, after construction ends and within 14 days following occupancy, using testing protocols consistent with the EPA Compendium of Methods for the Determination of Air Pollutants in Indoor Air or as the ISO method listed in the table below. Testing must be done in accordance with one standard; project teams may not mix requirements from the EPA Compendium of Methods with ISO."

100002077

At the end of the Establishment requirements, add:
Multifamily only
Meet the above requirements. Major end uses for multifamily projects may be defined as central building systems that represent 20% or more of the total annual energy consumption of the building.

Install an electricity meter for each unit.
At the end of the Performance requirements, add:

Multifamily only
On at least a monthly basis, provide residents access to their individual unit electricity consumption data.

100002081

At the end of the Waste Management Policy for Maintenance and Renovation, add:

• Furniture waste (Multifamily only). The policy should address storage locations for furniture and reuse or recycling of furniture waste.

100002083

"In bullet one, add:

(or at least 20% [1 point] or 40% [2 points] for Multifamily)/n

In bullet two, add:/n

(50% for Multifamily) "

100002084

"Under Mechanically Ventilated Spaces, above Case 1. Systems Able to Meet Required Outdoor Airflow Rates, add the following:
Multifamily only
Air-handling units serving common areas and residential units without operable windows must meet either Case 1 or Case 2.

100002088

Add rating system header EBOM, SCHOOLS, RETAIL, DATA CENTERS, HOSPITALITY, WAREHOUSES & DISTRIBUTION CENTERS directly above "Meet the requirements for both thermal comfort design and thermal comfort control."

At the end add of the existing rating system requirements, add a section for Multifamily:
ESTABLISHMENT
Have in place means of comfort control that allows occupants to optimize and control indoor comfort conditions (temperature, solar radiation, air speed, and humidity) within occupied residential spaces.

100002090

Under the Requirements header, add rating system header: "EBOM, SCHOOLS, RETAIL, DATA CENTERS, HOSPITALITY, WAREHOUSES & DISTRIBUTION CENTERS"
At the end of Option 1. Daylight, add the following:
MULTIFAMILY
ESTABLISHMENT
Option 1. Daylight Measurements (2 points)
Demonstrate through daylight measurements that illuminance levels comply with the following: