100002086

Option 1, after Warehouses and Distribution Centers ONLY box, add a new box with the following:
Multifamily only
Common area entrances shall meet the requirements above. For residential units with a direct entrance to the exterior, have in place a walk off mat.

100002072

Add two bullet points in the Establishment section:
• Residential unit-metering (Multifamily only). Meter at least 50% of residential units in the building. Provide consumption and cost data to individual residents.
• Residential unit-metering (Multifamily only). Meter 100% of residential units in the building. Provide consumption and cost data to individual residents.

100002126

Delete the following sentence:
"Project teams using exhaust ventilation systems must specify how outside air is delivered at the flow rate required by ASHRAE 62.2–2010."

100002142

In Requirements, under Furniture evaluation, revise the second sentence to read: Comply with ANSI/BIFMA e3-2011 Furniture Sustainability Standard, Sections 7.6.1 (for half credit, by cost) OR 7.6.2 (for full credit, by cost), using either the concentration modeling approach or the emissions factor approach.

ad-100001265

Add the following language for the new option 2: "Building materials or products shipped by rail or water have been extracted, harvested or recovered, as well as manufactured within a 500 mile (800 kilometer) total travel distance of the project site using a weighted average determined through the following formula: (Distance by rail/3) + (Distance by inland waterway/2) + (Distance by sea/15) + (Distance by all other means) ≤ 500 miles [800 kilometers]"

100002163

Change language to read as follows:
Option 1. Material Ingredient Reporting (1 point)
• Manufacturer Inventory. The manufacturer has published complete content inventory for the product following these guidelines:
o A publicly available inventory of all ingredients identified by name and Chemical Abstract Service Registration Number (CASRN) and/or European Community Number (EC Number)
o Materials defined as trade secret or intellectual property may withhold the name and/or CASRN/EC Number but must disclose role, amount and hazard screen using either:

100002157

Add prior to application after 24 hours so the sentence reads: "At a minimum, the facility manager must notify any building occupant or employee who requests it and post a sign at the application site, which must remain in place for 24 hours prior to application."

100002033

Revise Table 1 as follows:

1. Remove TO-15 from "ASTM and U.S. EPA methods" column
2. Add the full list of target chemicals, except formaldehyde, from CDPH Standard Method v1.1 in place of the single row (Target chemicals listed in CDPH Standard Method v1.1, Table 4.1, except formaldehyde) and revise the Maximum concentrations from CDPH Standard Method v1.1 2010, Allowable Concentrations, Table 4-1 with the Cal/EPA OEHHA full CREL in effect on June 2014.
3. reformat table for clarity

v4 Homes ENERGY STAR Clarifications

Rating System Correction 1: Requirements for Homes
Remove:
Meet the requirements of ENERGY STAR for Homes, version 3
Complete the thermal enclosure system rater checklist, the HVAC system quality installation rater and contractor checklists, and the water management system builder checklist. Certified passive house projects automatically meet the thermal enclosure system rater checklist requirement.