100001853

Table 2.
• WE Indoor Water Use (credit): Exemplary Performance “yes”
• EA Prereq Fundamental Commissioning and Verification" “C” in the Design/Construction column
• MR Credit Long-Term Commitment: “D” in the Design/Construction column
• Innovation and Regional Priority sections: “D/C” in the Design/Construction column

WE Indoor Water use (credit): Exemplary Performance section: “Achieve 55% water use reduction.”

100002201 - v4 ID+C Renewable Energy Production Guidance

Corrections for Step-by-Step Guidance section, Step 5:

In Equation 2, add the word 'cost' to the second factor in the equation, as shown below:
Equivalent cost of base building renewable energy = ($ value of renewable energy used in base building x % of base building energy cost delivered to project)

Corrections for Further Explanation > Renewable Energy Systems and Third Parties:

At the top of the section, add the following header: "Renewable Fuels Purchased Off-Site:"

100002200 - v4 BD+C Renewable Energy Production Guidance

Corrections for Further Explanation > Renewable Energy Systems and Third Parties:

At the top of the section, add the following header: "Renewable Fuels Purchased Off-Site:"

Replace the first sentence that begins with "Some renewable energy systems..." with the following: "Some renewable energy power generation systems that use fuels produced off site (e.g., landfill gas) can still be eligible to receive points under this credit if these fuels are harvested and produced within the same utility service area."

100002198 - CI Indoor Water Use step by step correction: Hospitality

Under Step 4. Select High-Efficiency specialized appliance and process water systems, where applicable, replace "Healthcare" with the word "Hospitality" so that the sentence reads as follows:

"Retail and Hospitality projects may earn additional points for selecting appliance or process water systems that meet the standards in the credit requirements."

100002619

Add fourth bullet under Formaldehyde Emissions: The VOC emissions evaluation documentation for any finish or treatment applied off-site (if applicable).

100002618

Add a second bullet under Required Documentation that reads as follows:

"For Interiors projects only: explain best practices for environmentally preferable purchasing for purchases outside of the project’s control"

100002617

Revise the first two sentences of the EP section to read as follows:

"Tier 1: renewable energy generation meets or exceeds 30% of total site energy use.
Tier 2: renewable energy procurement meets or exceeds 70% of total site energy use."