ad-100000796
At the end of the term\'s first sentence, insert the text "(see USDOE EIA CBECS survey for suggested default nonresidential occupancies)"
At the end of the term\'s first sentence, insert the text "(see USDOE EIA CBECS survey for suggested default nonresidential occupancies)"
Replace the seventh line of the first paragraph with the following:Existing streets and non-motorized streets are exempt from this credit, and projects with no internal streets are not eligible.
Replace the second sentence with the following:Building height is measured to eaves or the top of the roof for a flat-roof structure, and street width is measured fa
Revise connecitivity definition to the following: connectivity the number of publicly accessible intersections per square mile, including any combination of streets, dedicated alleys, transit rights-of-way, and nonmotorized rights-of-way. If one must both enter and exit an area through the same intersection, such an intersection and any intersections beyond that point are not counted; intersections leading only to culs-de-sac are also not counted.
Revise connecitivity definition to the following: connectivity the number of publicly accessible intersections per square mile, including any combination of streets, dedicated alleys, transit rights-of-way, and nonmotorized rights-of-way. If one must both enter and exit an area through the same intersection, such an intersection and any intersections beyond that point are not counted; intersections leading only to culs-de-sac are also not counted.
Replace the definition of "regularly occupied spaces" with "are areas where one or more individuals normally spend time (more than one hour per person per day on average) seated or standing as they work, study, or perform other focused activities inside a building."
The second new bullet should read: "Filtration media is Class F7 or higher, as defined by CEN Standard EN 779: 2002, Particulate air filters for general ventilation, Determination of the filtration performance"
The first new bullet should read: "Filtration media is rated at a minimum efficiency reporting value (MERV) of 13 or higher in accordance with ASHRAE Standard 52.2."
Add 3 new bullets below the second sub-bullet. Indent these bullets farther.
The second sub-bullet (5th bullet overall) should read: "These filters or devices shall meet one of the following criteria:"