Date
Inquiry

Our project is located in California and subject to compliance with Title 24 2019. Title 24 2019 has requirements for lighting power density more stringent than those requirements in ASHRAE 90.1-2010, and unfinished spaces in our project will be subject to the Title 24 2019 requirements.
For LEED credit compliance, our team plans to follow ASHRAE 90.1-2010 modeling. How can we document credit for Title 24 2019 compliant lighting in unfinished spaces?

Ruling

Building Type*
Unfinished Space Lighting Power Density
Automotive Facility
0.70
Convention Center
0.80
Courthouse
0.80
Dining: Bar Lounge/Leisure
0.75
Dining: Cafeteria/Fast Food
0.70
Dining: Family
0.70
Dormitory
0.61
Exercise Center
0.70
Fire Station
0.71
Gymnasium
0.80
Healthcare Clinic
0.87
Hospital
1.05
Hotel
1.00
Library
0.95
Manufacturing Facility
0.90
Motel
0.88
Motion Picture Theater
0.75
Multifamily
0.60
Museum
1.06
Office
0.72
Parking Garage
0.17
Penitentiary
0.97
Performing Arts Theater
1.10
Police Station
0.96
Post Office
0.8
Religious Building
0.85
Retail: Grocery
1.05
Retail
1.00
School/University
0.72
Sports Arena
0.78
Town Hall
0.85
Transportation
0.60
Warehouse
0.55
Workshop
1.10

Internationally Applicable
Off
Campus Applicable
Off