In the fourth line of the paragraph, remove the text "...Tables 1 and 2 summarize Green Seal Standard GS-11"
In the fourth line of the paragraph, remove the text "...Tables 1 and 2 summarize Green Seal Standard GS-11"
Below the table, replace the first sentence of the paragraph with the following:Determine, if applicable, the controller efficiency (CE), the percentage reduction in water use from any weather-based controllers or moisture sensor-based systems, not to exceed 30% for the peak month of July.
In the paragraph beginning with "Using groundwater...", replace the last sentence with the following:Additionally the credit can be met when landscape irrigation is provided by raw water (excluding naturally occurring surface bodies of water, streams, or rivers, and ground water) that would otherwise be treated specifically for nonpotable uses. Only ponds designed solely for the purposes of stormwater retention or detention can be used for this credit.
Replace the section text with the following:This prerequisite is limited to savings generated by the following water using fixtures and fixture fittings as applicable to the project: water closets, urinals, lavatory faucets, showers, kitchen sink faucets and pre-rinse spray valves, as shown in Table 1. The "Kitchen sinks" category encompasses all sinks in public or private buildings that are used with patterns and purposes similar to a sink in a residential kitchen; break room sinks would be included.
Replace text with the following:NC & SchoolsThis credit is not eligible for exemplary performance under the Innovation and Design section.CSProjects that require and enforce installing automatic controls within 100% of the tenant space are eligible for exemplary performance under the Innovation in Design section.
Replace the fourth line of the paragraph with "such as those for historic buildings, 24-hour facilities, and equipment and portions of building systems that use energy primarily to provide for industrial, manufacturing, or commercial processes."
Replace the section text with the following:The "Kitchen sinks" category encompasses all sinks in public or private buildings that are used with patterns and purposes similar to a sink in a residential kitchen; break room sinks would be included. However professional grade / commercial faucets such as those used in a commercial kitchen would not be included. The "Public lavatory faucets" and "Private lavatory faucets" categories encompass all sinks used primarily for hand-washing regardless of location.
Replace the image
In the image in the top left corner, change the reference from "b" to "a"
In the first line in the parenthesis, insert "or 9.6" after "9.5"