100002449

1. Remove “Building Product Disclosure and Optimization” from credit title
2. Under Option 1, replace the program list with the following:
• ANSI/BIFMA e3 Furniture Sustainability Standard. The documentation from the assessor or scorecard from BIFMA must demonstrate the product earned at least 3 points under 7.5.1.3 Advanced Level in e3-2014 or 3 points under 7.4.1.3 Advanced Level in e3-2012.

100002447

1. Remove “Building Product Disclosure and Optimization” from credit title
2. Under bio-based materials bullet, replace with following paragraph:

• Bio-based materials. Bio-based products and materials other than wood must be tested using ASTM Test Method D6866 or equivalent method ISO 16620-2, or be certified to the USDA BioPreferred Voluntary Labeling Initiative that includes verification via ASTM 6866 testing. Exclude hide products, such as leather and other animal skin material.

100002446

1. Remove “Building Product Disclosure and Optimization” from credit title
2. Option 1: Remove 'in which the manufacturer is explicitly recognized as the participant by the program operator' from Product-specific Type III EPD
3. Option 1 and Option 2: Remove 'USGBC approved program – Products that comply with other USGBC approved environmental product declaration frameworks'.
4. Option 2: In title, replace 'Multi-attribute Optimization' with 'Embodied carbon/LCA Optimization'

100002445

1.Modify point allocations for rating system versions as follows:
BD+C
1-6 points
This credit applies to
• BD+C: New Construction (1-5 points)
• BD+C: Core & Shell (1-6 points)
• BD+C: Schools (1-5 points)
• BD+C: Retail (1-5 points)
• BD+C: Data Centers (1-5 points)
• BD+C: Warehouses & Distribution Centers (1-5 points)
• BD+C: Hospitality (1-5 points)
• BD+C: Healthcare (1-5 points)

2. Re-title Option 1 as Building and Material Reuse (1-5 points BD+C, 2-6 points Core and Shell)

100002444

Delete the Construction and Demolition Waste Management Planning prerequisite and associated beta guidance in both BD+C and ID+C

100002431

1. Under the heading for the adaptations, insert new path title "Path 1. Access to Public Transit Service"

2. Within the fourth item in the bulleted list of criteria, insert "for Path 1" after "Privately-run shuttles are only acceptable"

3. Within the heading for Table 1 insert "public" between "daily" and "transit"

4. After the paragraph beginning "If existing transit service..." insert the following new language:

OR

Path 2. Access to Project-sponsored Transit Service

100002429

Under the Schools Only section, add Option 1, Table 1a and Table 1b from the requirements for NC, CS, Retail, and Hospitality. After the Option 1 heading, add "Path 1. Surrounding Density."

After the paragraph beginning "Physical education spaces..." add the following language for Path 2:

Path 2. Connected Site

Locate the project on a previously developed site that also meets one of the connected site conditions listed below.

Table 2. Points for connected site
Type of site Points
Adjacent 1
Infill 2

100002415

Under HVAC background noise, delete the last part of the sentence: "; the 2015 ASHRAE Handbook—HVAC Applications, Chapter 48, Sound and Vibration Control, with errata; AHRI Standard 885–2008; or a local equivalent."

100002411

Under Table 1, allowed test methods column, row 1 for carbon monoxide, Replace the accuracy for direct calibrated electrochemical instruments with "+/- 3% of reading and resolution of 0.1 ppm. NDIR CO Sensors with accuracy of 1% of 10 ppm full scale and display resolution of less than 0.1ppm"