100002216

Table 1. Minimum ventilation area

Continuous ventilation

Intermittent ventilation

Single-sided

0,35 m² / person

1,05 m² / 10 m² room area

Cross-ventilation

0,2 m² / person

0,6 m² / 10 m² room area

100002219 - Europe ACP Reduced Parking Footprint

International Tips section added to provide supporting guidance for the Europe ACP:

"Preferred Parking for Carpools and Shared-Use Vehicles
For European projects pursuing Case 2, provide preferred parking for carpool or shared-use vehicles for 5% of the total parking spaces after reductions are made from the base ratios. Preferred parking is not required if no off-street parking is provided.

ad-100001177

After the first sentence, add the following: "If an energy model was used to document compliance with EAc1: Optimize Energy Performance, the data from the energy model must be used as the basis for determining the electricity consumption for this credit."

ad-100001176

After the first sentence, add the following: "If an energy model was used to document compliance with EAc1.3: Optimize Energy Performance, HVAC, the data from the energy model must be used as the basis for determining the electricity consumption for this credit."