100002320 v4 Midrise Annual Energy Use typo

Current language reads: Follow the criteria in EA Prerequisite Performance for Energy Star Homes to demonstrate a percentage improvement in the proposed building’s performance compared with the baseline building performance of ASHRAE 90.1–2010, or USGBC-approved equivalent standard for projects outside the U.S. Points are awarded according to Table 5.

Replace the term "EA Prerequisite Performance for Energy Star Homes" with the following: "EA Prerequisite Minimum Energy Performance."

100002318 waste performance score description

Replace equations 1 through 5 with:

Equation 1. Average daily waste generated = (waste generated / # days associated with waste total) / occupancy
The waste diverted is converted into a daily waste undiverted per occupant, using Equation 2.
Equation 2. Daily waste undiverted per occupant = (waste diverted / # days associated with waste total) / occupancy
The daily undiverted waste is calculated using Equation 3.
Equation 3. Daily undiverted waste per occupant = daily waste generated per occupant– daily waste diverted per occupant

100002332 - Remove turfgrass requirement Homes outdoor water use

Under Option 1. Efficient Landscaping (1-4 points), make the following changes:

Revise the first sentence to read "Landscape with plants that are native or adapted to the region."

Revise title for "Table 1. Points for reducing turf grass and increasing native plantings, as percentage of total landscape area" to read: "Table 1. Points for increasing native plantings, as percentage of total landscape area"

Remove column 1 "Turf grass area" and column "and" from Table 1.