ad-100000585
"Early in the design process... extracted, harvested, recovered, or manufactured locally..." change to "Early in the design process... extracted, harvested, recovered, and manufactured locally..."
"Early in the design process... extracted, harvested, recovered, or manufactured locally..." change to "Early in the design process... extracted, harvested, recovered, and manufactured locally..."
"Projects that use more than 16 of the options in Table 1 and earn more than the maximum 8 points can earn additional points, to be counted under Innovation & Design 3." change to "Projects that install more than 16 of the measures listed in MR 2.2 should be awarded exemplary performance points, to be counted under Innovation & Design 3."
Replace table
"Waste Diverted = Total Waste Hauled - Waste Sent to Landfill + Waste Incinerated" change to "Waste Diverted = Total Waste Hauled - (Waste Sent to Landfill + Waste Incinerated)"
Insert the term "Tenant space" in alphabetical order with the accompanying text "Tenant space is the area within the LEED project boundary. For more information on what can and must be in the LEED project boundary see the Minimum Program Requirements (MPRs) and LEED 2009 MPR Supplemental Guidance. Note: tenant space is the same as project space."
Insert the term "Tenant space" in alphabetical order with the accompanying text "Tenant space is the area within the LEED project boundary. For more information on what can and must be in the LEED project boundary see the Minimum Program Requirements (MPRs) and LEED 2009 MPR Supplemental Guidance. Note: tenant space is the same as project space."
Insert the term "Bay" in alphabetical order with the accompanying text "A bay is a component of a standard, rectilinear building design. It is the open area defined by a building element such as columns or a window. Typically, there are multiple identical bays in succession."
Insert the term "Tenant space" in alphabetical order with the accompanying text "Tenant space is the area within the LEED project boundary. For more information on what can and must be in the LEED project boundary see the Minimum Program Requirements (MPRs) and LEED 2009 MPR Supplemental Guidance. Note: tenant space is the same as project space."
Remove the fifth paragraph of the section:Even though this credit does not require a monitoring system in additionto occupant surveying to verify the thermal comfort conditions, it mightbe beneficial for the owner and design teams to employ both options intheir operations and maintenance plan, especially for determiningoptions for corrective action.
In alphabetical order, insert the terms:In alphabetical order, insert the terms:Private or private use applies to plumbing fixtures in residences,apartments, and dormitories, to private (non-public) bathrooms intransient lodging facilities (hotels and motels), and to private bathroomsin hospitals and nursing facilities.Public or public use applies to all buildings, structures, or uses that are not defined as private or private use.