In the credit calculator, under the Low-emitting criteria column (for Flooring, Wall panels, Ceilings, and Insulation) the drop down box has options for VOC emissions evaluation Option 1 or VOC emissions evaluation Option 2. I don't see an explanation for what Option 1 and Option 2 are in the reference guide. Any ideas? Thanks!
You rely on LEEDuser. Can we rely on you?
LEEDuser is supported by our premium members, not by advertisers.
VOC emissions evaluation:
Option 1: Product has been tested according to California Department of Public Health (CDPH) Standard Method v1.2–2017 and complies with the VOC limits in Table 4-1 of the method.
Option 2: Product has been tested according to EN 16516:2017 and complies with the LCI values from Table 1 of the German AgBB Testing and Evaluation Scheme (2015) and a formaldehyde limit of 10 micrograms per cubic meter.
Add new comment