Dear All,
We have an existing office (around 2-3 years old) which we want to get LEED certified. However, it is a part (tenant space) of mixed-use building. It is not clear to me which rating system to select as LEED O&M rating is for existing whole building and not for tenant spaces.
Would it be acceptable to apply for LEED CI or any other rating system?
Request your valuable suggestions on the same.
Thanks and Regards,
Shijo John
Tristan Roberts
RepresentativeVermont House of Representatives
LEEDuser Expert
11478 thumbs up
April 10, 2016 - 7:58 am
Shijo, as you indicate, LEED-EBOM is for whole buildings. Yet, LEED-CI is not really applicable because it is designed around significant fit-out being done on the space.