More natural light is transmitted through glazing with higher VLT values, but higher VLT values tend to correlate with higher solar heat gain coefficients (SHGC). Assess the optimal balance of these values, along with
Find out the Visual Light Transmittance (VLT) value of the glazing and enter it on the LEED credit form for each occupied space. The VLT is usually included with the glazing specifications.
Some applicable spaces may be exempt from the daylighting calculation if their uses are daylight-sensitive. Examples include museum or gallery spaces, auditoriums and high-security areas. If you have daylight-sensitive spaces in your project that you would like to exempt from the calculation, you must provide a detailed narrative explanation and exemption request along with the credit documentation. This requests are scrutinized carefully, however, and may not be successful.
Identify regularly occupied spaces that need to be included in the LEED daylight calculation. Locate these spaces near perimeter glazing, courtyards, or other daylight sources.
If allowing smoking in some units, clustering those rooms on one floor can keep the need for special air sealing and hallway pressurization strategies (which can be used in lieu of weatherstripping) relatively contained.
Designate the location of outdoor smoking areas, if any, on design drawings. Ensure that these areas are appropriately removed from building windows, ventilation opens, and entrances, and entrance paths.
Incorporate smoking-related requirements into the commissioning documentation, including the Owner’s Project Requirements and the Basis of Design for EAp1: Fundamental Commissioning.
If a LEED project includes both existing structure and new construction, the LEED project boundary must encompass the entire existing building regardless of the scope of work within the existing building.