The mechanical engineer begins preliminary ventilation rate calculations during project programming in order to set ventilation quality goals for particular spaces and occupancies.

The mechanical engineer begins preliminary ventilation rate calculations during project programming in order to set ventilation quality goals for particular spaces and occupancies. The area of a given multi‐zone system should be broken down by ventilation zones, and all zones within that system must meet the minimum breathing zone ventilation air requirements as per ASHRAE 62.1‐2004. For a typical office space, the mechanical design consists of multiple ventilation zones for which compliance would need to be shown on an individual basis.

Separately evaluate each space to determine air requirements and what type of ventilation will be best.  Metabolic rate of the space activities and the occupant density are factors that determine the amount of fresh air needed in a space.  For e

Separately evaluate each space to determine air requirements and what type of ventilation will be best.  Metabolic rate of the space activities and the occupant density are factors that determine the amount of fresh air needed in a space.  For example, exercise rooms and conference rooms require more fresh air than offices.

Consider the cost implications of natural ventilation. Passive strategies may reduce or eliminate the need for fans and HVAC equipment, but they may also require high quantities of operable windows and a floor plan that is conducive to passive ventilation

Consider the cost implications of natural ventilation. Passive strategies may reduce or eliminate the need for fans and HVAC equipment, but they may also require high quantities of operable windows and a floor plan that is conducive to passive ventilation.  Natural ventilation often requires the cooperation of occupants, to open and close windows when appropriate, for example, be sure that your project is likely to succeed in this respect.

Naturally ventilated core and shell projects must provide the potential for tenant build-out to meet requirements of this credit.  When documenting the credit, you can provide an assumed tenant layout and default occupancy assumptions based on the LE

Naturally ventilated core and shell projects must provide the potential for tenant build-out to meet requirements of this credit.  When documenting the credit, you can provide an assumed tenant layout and default occupancy assumptions based on the LEED Reference Guide Appendix 1 to confirm that tenant spaces meet ASHRAE 62.1 requirements.

Airflow modeling early in the design process can help teams create a more effective natural ventilation design. If the data is used early in the design to help inform team on such thing as space planning and building envelope design. An airflow modeling p

Airflow modeling early in the design process can help teams by evaluating which space planning and envelope design strategies will create effective natural ventilation. An airflow modeling professional may add some upfront costs, while likely improving system efficiency.

 Airflow modeling can also help to determine compliance for an engineered natural ventilation system outside the prescriptive measures of ASHRAE 62.1-2007.