100002019

Move bullet number 3 before bullet number 2 and renumber accordingly.
Add the following text at the beginning of the “Creating the Baseline Building”:
"The baseline building design shall be a design that exhibits industry-standard materials and practices for a building that meets the functional requirements of the project. The actual design should demonstrate a design that deviates from those industry-standard materials and practices – for example, the use of lower-impact materials or dematerialization, or a system not commonly used in that application.

100001993

Add the following language under Campus Approach section:
"Eligible. Projects can demonstrate compliance with a campus-wide no-smoking policy in lieu of building signage. The policy must be widely communicated to all occupants (including transients and visitors) through ongoing methods such as site signage and other media (brochures, websites, etc.)."

100002336 - Advanced Energy Metering Guidance

In Further Explanation, Determining Major Energy End Uses, before the paragraph starting with “Choosing what equipment and components to group”, add the following paragraph:

It is acceptable to exclude a small portion of the total loads from each end-use category. Not more than 10% of the total connected load of any of the required end-uses is permitted to be excluded from that end-use advanced metering data collection. Not more than 10% of the total connected load of any of the end-uses where metering is required is permitted to consist of loads not part of that end-use.

ad-100000438

Insert the term "Bay" in alphabetical order with the accompanying text "A bay is a component of a standard, rectilinear building design. It is the open area defined by a building element such as columns or a window. Typically, there are multiple identical bays in succession."

ad-100000434

At the end of the paragraph, add the addition text "For residential projects, the occupants have a higher level of control over the building systems and are therefore not eligible for this credit."

ad-100000432

Replace the second paragraph with the following text:During the design phase, the architect should consider the location andtype of entryway systems and allow adequate space for entryway systems.During the schematic design phase, the team should confirm the locationsof areas where chemicals and high-volume copy, fax, and print equipmentwill be used. It may be possible to locate such rooms above or adjacent to1 another to make individual exhaust systems unnecessary and minimizeexhaust ductwork. Also confirm that chemical and equipment rooms areproperly isolated from adjacent spaces.