ad-100000745

Add in the following section:Eligible FixturesThis prerequisite is limited to savings generated by the following water using fixtures and fixture fittings as applicable to the project: water closets, urinals, lavatory faucets, showers, kitchen sink faucets and pre-rinse spray valves, as shown in Table 1. The "Kitchen sinks" category encompasses all sinks in public or private buildings that are used with patterns and purposes similar to a sink in a residential kitchen; break room sinks would be included.

ad-100000960

In item 2, add "skylights" to the list of things deducted from the roof area so that the sentence reads, "Determine the area of the roof covered by mechanical equipment, solar energy panels, skylights, and other appurtenances, and deduct these areas from the total roof surface area."

ad-100001131

Replace the definition for group multioccupant spaces with the following definition for multi-occupant space, "Multi occupant spaces are places of egress, congregation, or where occupants pursue overlapping or collaborative tasks. Multi occupant spaces may be regularly or non-regularly occupied spaces."

ad-100001130

Replace the definition for group multioccupant spaces with the following definition for multi-occupant space, "Multi occupant spaces are places of egress, congregation, or where occupants pursue overlapping or collaborative tasks. Multi occupant spaces may be regularly or non-regularly occupied spaces."

ad-100001140

Revise the definition for regularly occupied spaces to be, "Regularly occupied spaces are areas where one or more individuals normally spend time (more than one hour per person per day on average) seated or standing as they work, study, or perform other focused activities inside a building."

ad-100000963

In alphabetical order, add the term "An appurtenance is any built-in, nonstructural portion of a roof system, such as skylights, ventilators, mechanical equipment, partitions, and solar energy panels."