Credits

Add in the following section:Eligible FixturesThis prerequisite is limited to savings generated by the following water using fixtures and fixture fittings as applicable to the project: water closets, urinals, lavatory faucets, showers, kitchen sink faucets and pre-rinse spray valves, as shown in Table 1. The "Kitchen sinks" category encompasses all sinks in public or private buildings that are used with patterns and purposes similar to a sink in a residential kitchen; break room sinks would be included. However professional grade / commercial faucets such as those used in a commercial kitchen would not be included. The "Public lavatory faucets" and "Private lavatory faucets" categories encompass all sinks used primarily for hand-washing regardless of location. Faucets whose usage patterns and flow rates are regulated for medical or industrial purposes (e.g. laboratory sinks) and do not fall under the definition of private or public use are not included. Faucets used exclusively for filling operations (e.g. pot-filler) can be excluded. All other fixtures and fixtures fittings must be included in the calculations unless there are special circumstances that justify excluding them.

Date
Updated date
Campus Applicable
Off
Internationally Applicable
Off
Ref Guide Name and Edition Pre-v4
Green Building Operations and Maintenance, 2009 edition$Green Building Operations and Maintenance, 2009 edition, updated April 2010