Forum discussion

CS-v4 EAp2:Minimum energy performance

EA P2 Window to wall ratio

Hi, 

I am modelling a CS building, the facade for the core (stairs, restroom, elevators, and all  non conditioned area) is 100% wall am I allowed to model it as non conditioned area but considering the wall to reduce the window to wall ratio?

Thanks 

 

0

You rely on LEEDuser. Can we rely on you?

LEEDuser is supported by our premium members, not by advertisers.

Go premium for $15.95  »

Wed, 04/11/2018 - 23:48

If all those spaces are not conditioned then any exterior walls associated with those spaces would not be considered a part of the exterior envelop. So you should model those spaces as unconditioned if they are unconditioned. You cannot count the wall area associated with these spaces in the window to wall ratio because that only include the envelop associated with conditioned spaces.