Coating on process equipment applied onsite

Hello all, I am working on an industrial manufacturing building where a piece of the process equipment will be painted onsite as part of the installation requirements, but as it is part of the equipment and not part of the building, I was wondering if this coating should comply with the VOC limits, since the VOC content is 450 and I don´t know where to classify this coating. Thank you in advance. Regards!

2

You rely on LEEDuser. Can we rely on you?

LEEDuser is supported by our premium members, not by advertisers.

Go premium for $15.95  »

Thu, 07/02/2015 - 03:28

Even though industrial process equipment typically is furnished by the owner or tenant and not part of the normal construction scope, I believe that IEQc4.2 VOC limits still apply. Since the painting occurs onsite and inside the building during the construction period, the paint must meet SCAQMD or CARB VOC limits. Furthermore, SCAQMD-1113-2004 & CARB-2007-SCM each say that they cover coatings for “fixed stationary tools” that are accessory to a building. I think that this includes equipment such as you describe. Classify the paint by comparing its characteristics to SCAQMD & CARB definitions. If it contains metal flakes, the paint may be a Metallic Pigmented Coating with a VOC limit of 450g/L. Otherwise, if it is anticorrosive, it may be an Industrial Maintenance or Anti-Corrosive paint limited to 250g/L VOC. If the paint exceeds the prescribed VOC limit, a budget calculation may become necessary. In any case, if the equipment installers do the painting, make sure that they are bound by the project’s IAQ Management Plan and that they use precautions to avoid fouling IEQc3 pre-occupancy IAQ tests.

Add new comment

To post a comment, you need to register for a LEEDuser Basic membership (free) or login to your existing profile.