Are fire exits/emergency stairs considered part of the roof or can these be excluded?
You rely on LEEDuser. Can we rely on you?
LEEDuser is supported by our premium members, not by advertisers.
Go premium forForum discussion
NC-2009 SSc7.2: Heat Island Effect—Roof
Are fire exits/emergency stairs considered part of the roof or can these be excluded?
LEEDuser is supported by our premium members, not by advertisers.
Go premium forTo post a comment, you need to register for a LEEDuser Basic membership (free) or login to your existing profile.
We don't know the SRI value of some roofing materials we are using. What should we do?
Do balconies and terraces need to be counted towards the roof square footage?
How does one calculate the square footage of a pitched roof?
Tristan Roberts
RepresentativeVermont House of Representatives
LEEDuser Expert
11477 thumbs up
January 6, 2014 - 12:11 pm
MM, per the guidance above, appurtenances such as mechanical equipment, skylights, pools, helipads, and more are excluded. The terminology used is "functional, usable spaces." I haven't seen stairs mentioned on a list of exclusions but it seems like they fit the mold.
Mike D
56 thumbs up
January 6, 2014 - 12:28 pm
Thanks Tristan!
On another note, when part of the roof is covered by louvres that do not fully shade the roof (i.e., lets in strips of sunlight in), which part has to be documented, the roof or the louvres?
Tristan Roberts
RepresentativeVermont House of Representatives
LEEDuser Expert
11477 thumbs up
January 6, 2014 - 12:46 pm
What are the louvres covering? Just roof? That's a bit of an odd case, and I could see an argument for going one of three ways.If the louvres are over a skylight, which makes more sense to me funtionally, it would be an appurtenance.
Susan Walter
HDRLEEDuser Expert
1296 thumbs up
January 6, 2014 - 1:13 pm
Be careful on the stairs, if you have covered, conditioned stairs leading up to the roof that stair roof IS part of the calculation. Ask me how I know.
Kathryn West
LEED AP BD+C, O+M, Green Globes ProfessionalJLL
154 thumbs up
January 6, 2014 - 2:38 pm
I'd like to echo what Susan said. Example: If a football stadium has seating/stairs covering enclosed floor area: that's a roof! There is a Reference Guide addition ID#100000972 that defines "Roof area" as "the area of the uppermost surface of the building which covers enclosed Gross Floor Area, as measured when projected onto a flat, horizontal surface (i.e. as seen in Roof Plan view). \'Roofs\', or portions of roofs, covering unenclosed areas (e.g. roofs over porches and open covered parking structures) are not included in the areas used to evaluate compliance with SSc7.2, though they may be applicable to SSc7.1." I'd read that closely and interpret it very literally. Look at your project in roof plan view. If the area covers enclosed gross floor area then include it in your calculation.
Mike D
56 thumbs up
January 16, 2014 - 5:49 am
The stairs are not covered or conditioned. They are just emergency exit stairs.
About the louvres, if they partly cover the terraces on the roof (the terraces are not conditioned and the louvres only cover half of the terraces for shading purposes), should these be included in the calculations or should we include the paving of the terraces in the calculations?
Susan Walter
HDRLEEDuser Expert
1296 thumbs up
January 16, 2014 - 1:17 pm
I would say the stairs are not a part of your calculations. I would ignore the louvers and call them shading devices which equal appurtenances. The paving should be counted.
Mara Baum
Partner, Architecture & SustainabilityDIALOG
674 thumbs up
January 16, 2014 - 1:31 pm
I have previously been asked to include louver-like systems in the calculations, especially if they cover a significant amount of roof area. If it's more like a trellis, with relatively little coverage, then you can probably skip it.