Hello.
my project is in outside of USA.
Because of that, there are many obstacles to get NFRC test about fenestration.
can i omit this test in my project?
You rely on LEEDuser. Can we rely on you?
LEEDuser is supported by our premium members, not by advertisers.
Go premium for
Marcus Sheffer
LEED Fellow7group / Energy Opportunities
LEEDuser Expert
5909 thumbs up
May 24, 2012 - 4:11 pm
No project, inside or outside the US, must use NFRC rated windows.
Jean Marais
b.i.g. Bechtold DesignBuilder Expert832 thumbs up
May 30, 2012 - 11:39 am
Are you talking about air leakage or heat transmission properties?
Marcus Sheffer
LEED Fellow7group / Energy Opportunities
LEEDuser Expert
5909 thumbs up
May 30, 2012 - 12:05 pm
Just talking about NFRC ratings not the window properties they test for. The window properties must be modeled based on the most accurate data which can reasonably be provided or derived.
Mathilda Jonsson
Environmental Certification Engineer (LEED AP BD+C)Skanska
41 thumbs up
November 15, 2012 - 5:53 am
Hi
Working with LEED projects in Sweden and have a bit of trouble interpreting some of the terminologies & requirements of the Mandatory Provisions for Building Envelope. The the u-value and SGHC of fenestrations are to be determinated using NFRC, which is not possible here. Are you saying that the project doesn't need to have fenestartion that are tested according to NFRC? We've talked to experts and they can't compare the ISO standrad that our fenestration usually are tested according to with NFRC.
Marcus Sheffer
LEED Fellow7group / Energy Opportunities
LEEDuser Expert
5909 thumbs up
November 19, 2012 - 12:03 pm
Yes they do not need to be NFRC tested for international projects. Simply provide the window performance parameters and if asked provide the testing or other data to back it up.