Log in

Best Practices

Make sure mechanical spaces and locations are coordinated in the architectural and structural drawings. For example, is a duct run colliding with a beam? Is a fan coil unit placed above a door opening so that it will leak condensate on people walking into

Make sure mechanical spaces and locations are coordinated in the architectural and structural drawings. For example, is a duct run colliding with a beam? Is a fan coil unit placed above a door opening so that it will leak condensate on people walking into the space? Common mistakes like this can cause construction delays and poor performance during operations if not detected, so coordination of the drawings is critical, especially if your project involves integrated design and complex systems. 

Use your energy model to review envelope thermal and hygrothermal performance. In a heating climate, thick insulation inside the air barrier may cause condensation problems. Consider an exterior thermal barrier to protect the air barrier and to prevent co

Use your energy model to review envelope thermal and hygrothermal performance. In a heating climate, thick insulation inside the air barrier may cause condensation problems. Consider an exterior thermal barrier to protect the air barrier and to prevent condensation inside the wall cavity. Identify thermal bridges in the walls and windows that could leak heat from inside. Add thermal breaks, such as neoprene gaskets, on shelf angles, silicone beading on window frames, and use other techniques to prevent leakage from the envelope. 

Daylighting makes for welcoming spaces, and can save energy both through reduced electric lighting and reduced cooling load due to the reduced electric lighting. Consider an atrium and skylights to serve ventilation and light functions. Integrate spatial

Daylighting makes for welcoming spaces, and can save energy both through reduced electric lighting and reduced cooling load due to the reduced electric lighting. Consider an atrium and skylights to serve ventilation and light functions. Integrate spatial programming within the atrium to utilize the space. See LEEDuser’s daylighting strategy for more.

Up to three LEED points are available under Option 3 for compliance with the Core Performance Guide. It’s a good option if your project is smaller than 100,000 ft2, does not fall into one of the Option 2 categories and you’d rather not commit to energy mo

Up to three LEED points are available under Option 3 for compliance with the Core Performance Guide. It’s a good option if your project is smaller than 100,000 ft2, does not fall into one of the Option 2 categories and you’d rather not commit to energy modeling (Option 1). Your project automatically earns one point for meeting the prerequisite. An additional one or two points are available for meeting any three or six requirements, respectively, of Section 3.