Log in
LEED v4
Hospitality – Commercial Interiors
Location & Transportation

Reduced parking footprint

LEED CREDIT

Hospitality-CI-v4 LTc5: Reduced parking footprint 1-2 points

See all forum discussions about this credit »
View the LEED v4.1 version of this credit »

SPECIAL REPORT

LEEDuser expert

Marilyn Specht

LEED AP (ND, O+M), WELL AP, LFA, Fitwel Ambassador, EcoDistricts AP

SmithGroup
Senior Principal | Director of Sustainability Integration

SPECIAL REPORT

LEEDuser’s viewpoint

Frank advice from LEED experts

LEED is changing all the time, and every project is unique. Even seasoned professionals can miss a critical detail and lose a credit or even a prerequisite at the last minute. Our expert advice guides our LEEDuser Premium members and saves you valuable time.

Credit language

USGBC logo

© Copyright U.S. Green Building Council, Inc. All rights reserved.

Requirements

Do not exceed the minimum local code requirements for parking capacity. Provide parking capacity that is a percentage reduction below the base ratios recommended by the Parking Consultants Council, as shown in the Institute of Transportation Engineers’ Transportation Planning Handbook, 3rd edition, Tables 18-2 through 18-4.

Case 1. Baseline location
Projects that have not earned points under LT Credit Surrounding Density and Diverse Uses or LT Credit Access to Quality Transit must achieve a 20% (1 point) or 40% (2 points) reduction from the base ratios.
Case 2. Dense and/or transit-served location
Projects earning 1 or more points under either LT Credit Surrounding Density and Diverse Uses or LT Credit Access to Quality Transit must achieve a 40% (1 point) or 60% (2 points) reduction from the base ratios.
For all projects
The credit calculations must include all existing and new off-street parking spaces that are leased or owned by the project, including parking that is outside the project boundary but is used by the project. On-street parking in public rights-of-way is excluded from these calculations.

For projects that use pooled parking, calculate compliance using the project’s share of the pooled parking.

Provide preferred parking for carpools for 5% of the total parking spaces after reductions are made from the base ratios. Preferred parking is not required if no off-street parking is provided.

Mixed-use projects should determine the percentage reduction by first aggregating the parking amount of each use (as specified by the base ratios) and then determining the percentage reduction from the aggregated parking amount.

Do not count parking spaces for fleet and inventory vehicles unless these vehicles are regularly used by employees for commuting as well as business purposes.

Alternative Compliance Paths (ACPs)

Europe ACP: Reduced Parking Footprint
For European projects pursuing Case 2, provide preferred parking for carpool or shared-use vehicles for 5% of the total parking spaces after reductions are made from the base ratios. A discounted parking rate of at least 20% for carpool vehicles is an acceptable substitute for preferred parking spaces. The discounted rate must be publicly posted at the entrance of the parking area and permanently available to every qualifying vehicle. See all forum discussions about this credit »

What does it cost?

Cost estimates for this credit

On each BD+C v4 credit, LEEDuser offers the wisdom of a team of architects, engineers, cost estimators, and LEED experts with hundreds of LEED projects between then. They analyzed the sustainable design strategies associated with each LEED credit, but also to assign actual costs to those strategies.

Our tab contains overall cost guidance, notes on what “soft costs” to expect, and a strategy-by-strategy breakdown of what to consider and what it might cost, in percentage premiums, actual costs, or both.

This information is also available in a full PDF download in The Cost of LEED v4 report.

Learn more about The Cost of LEED v4 »

Frequently asked questions

Can this credit be achieved if the project has no existing parking and is providing no new parking?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

I don’t have a copy of the Transportation Planning Handbook. How do I determine the base ratio for my project?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

My mixed-use building contains space types that aren’t listed in the Base Ratios table in the Reference Guide. How do I calculate the base ratio for my project? 

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

See all forum discussions about this credit »

Addenda

4/6/2018Updated: 11/6/2020
Regional ACP
Description of change:
International Tips section added to provide supporting guidance for the Europe ACP:

"Preferred Parking for Carpools and Shared-Use Vehicles
For European projects pursuing Case 2, provide preferred parking for carpool or shared-use vehicles for 5% of the total parking spaces after reductions are made from the base ratios. Preferred parking is not required if no off-street parking is provided.

Discounted Parking Rate
For projects pursuing Case 2 which will require payment for parking, a discounted parking rate of at least 20% for carpool vehicles is an acceptable substitute for preferred parking spaces."

Europe ACP added to Requirements section:
"Europe ACP: Reduced Parking Footprint
For European projects pursuing Case 2, provide preferred parking for carpool or shared-use vehicles for 5% of the total parking spaces after reductions are made from the base ratios. A discounted parking rate of at least 20% for carpool vehicles is an acceptable substitute for preferred parking spaces. The discounted rate must be publicly posted at the entrance of the parking area and permanently available to every qualifying vehicle."
Campus Applicable
No
Internationally Applicable:
No
4/6/2018Updated: 11/6/2020
Reference Guide Correction
Description of change:
International Tips section added to provide supporting guidance for the Europe ACP:

"Preferred Parking for Carpools and Shared-Use Vehicles
For European projects pursuing Case 2, provide preferred parking for carpool or shared-use vehicles for 5% of the total parking spaces after reductions are made from the base ratios. Preferred parking is not required if no off-street parking is provided.

Discounted Parking Rate
For projects pursuing Case 2 which will require payment for parking, a discounted parking rate of at least 20% for carpool vehicles is an acceptable substitute for preferred parking spaces."

Europe ACP added to Requirements section:
"Europe ACP: Reduced Parking Footprint
For European projects pursuing Case 2, provide preferred parking for carpool or shared-use vehicles for 5% of the total parking spaces after reductions are made from the base ratios. A discounted parking rate of at least 20% for carpool vehicles is an acceptable substitute for preferred parking spaces. The discounted rate must be publicly posted at the entrance of the parking area and permanently available to every qualifying vehicle."
Campus Applicable
No
Internationally Applicable:
No
1/11/2019Updated: 1/31/2019
Reference Guide Correction
Description of change:
Original:
"Projects with separate parking areas for visitors, employees or students must apply the proportion of preferred parking for carpools must be applied to each pool of parking."

Change to:
"Projects with separate parking areas for visitors, employees, or students must apply the proportion of preferred parking for carpools to each pool of parking."
Campus Applicable
No
Internationally Applicable:
Yes
See all forum discussions about this credit »

Documentation toolkit

The motherlode of cheat sheets

LEEDuser’s Documentation Toolkit is loaded with calculators to help assess credit compliance, tracking spreadsheets for materials, sample templates to help guide your narratives and LEED Online submissions, and examples of actual submissions from certified LEED projects for you to check your work against. To get your plaque, start with the right toolkit.

LEEDuser expert

Marilyn Specht

LEED AP (ND, O+M), WELL AP, LFA, Fitwel Ambassador, EcoDistricts AP

SmithGroup
Senior Principal | Director of Sustainability Integration

Get the inside scoop

Our editors have written a detailed analysis of nearly every LEED credit, and LEEDuser premium members get full access. We’ll tell you whether the credit is easy to accomplish or better left alone, and we provide insider tips on how to document it successfully.

USGBC logo

© Copyright U.S. Green Building Council, Inc. All rights reserved.

Requirements

Do not exceed the minimum local code requirements for parking capacity. Provide parking capacity that is a percentage reduction below the base ratios recommended by the Parking Consultants Council, as shown in the Institute of Transportation Engineers’ Transportation Planning Handbook, 3rd edition, Tables 18-2 through 18-4.

Case 1. Baseline location
Projects that have not earned points under LT Credit Surrounding Density and Diverse Uses or LT Credit Access to Quality Transit must achieve a 20% (1 point) or 40% (2 points) reduction from the base ratios.
Case 2. Dense and/or transit-served location
Projects earning 1 or more points under either LT Credit Surrounding Density and Diverse Uses or LT Credit Access to Quality Transit must achieve a 40% (1 point) or 60% (2 points) reduction from the base ratios.
For all projects
The credit calculations must include all existing and new off-street parking spaces that are leased or owned by the project, including parking that is outside the project boundary but is used by the project. On-street parking in public rights-of-way is excluded from these calculations.

For projects that use pooled parking, calculate compliance using the project’s share of the pooled parking.

Provide preferred parking for carpools for 5% of the total parking spaces after reductions are made from the base ratios. Preferred parking is not required if no off-street parking is provided.

Mixed-use projects should determine the percentage reduction by first aggregating the parking amount of each use (as specified by the base ratios) and then determining the percentage reduction from the aggregated parking amount.

Do not count parking spaces for fleet and inventory vehicles unless these vehicles are regularly used by employees for commuting as well as business purposes.

Alternative Compliance Paths (ACPs)

Europe ACP: Reduced Parking Footprint
For European projects pursuing Case 2, provide preferred parking for carpool or shared-use vehicles for 5% of the total parking spaces after reductions are made from the base ratios. A discounted parking rate of at least 20% for carpool vehicles is an acceptable substitute for preferred parking spaces. The discounted rate must be publicly posted at the entrance of the parking area and permanently available to every qualifying vehicle.

Cost estimates for this credit

On each BD+C v4 credit, LEEDuser offers the wisdom of a team of architects, engineers, cost estimators, and LEED experts with hundreds of LEED projects between then. They analyzed the sustainable design strategies associated with each LEED credit, but also to assign actual costs to those strategies.

Our tab contains overall cost guidance, notes on what “soft costs” to expect, and a strategy-by-strategy breakdown of what to consider and what it might cost, in percentage premiums, actual costs, or both.

This information is also available in a full PDF download in The Cost of LEED v4 report.

Learn more about The Cost of LEED v4 »

Can this credit be achieved if the project has no existing parking and is providing no new parking?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

I don’t have a copy of the Transportation Planning Handbook. How do I determine the base ratio for my project?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

My mixed-use building contains space types that aren’t listed in the Base Ratios table in the Reference Guide. How do I calculate the base ratio for my project? 

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

4/6/2018Updated: 11/6/2020
Regional ACP
Description of change:
International Tips section added to provide supporting guidance for the Europe ACP:

"Preferred Parking for Carpools and Shared-Use Vehicles
For European projects pursuing Case 2, provide preferred parking for carpool or shared-use vehicles for 5% of the total parking spaces after reductions are made from the base ratios. Preferred parking is not required if no off-street parking is provided.

Discounted Parking Rate
For projects pursuing Case 2 which will require payment for parking, a discounted parking rate of at least 20% for carpool vehicles is an acceptable substitute for preferred parking spaces."

Europe ACP added to Requirements section:
"Europe ACP: Reduced Parking Footprint
For European projects pursuing Case 2, provide preferred parking for carpool or shared-use vehicles for 5% of the total parking spaces after reductions are made from the base ratios. A discounted parking rate of at least 20% for carpool vehicles is an acceptable substitute for preferred parking spaces. The discounted rate must be publicly posted at the entrance of the parking area and permanently available to every qualifying vehicle."
Campus Applicable
No
Internationally Applicable:
No
4/6/2018Updated: 11/6/2020
Reference Guide Correction
Description of change:
International Tips section added to provide supporting guidance for the Europe ACP:

"Preferred Parking for Carpools and Shared-Use Vehicles
For European projects pursuing Case 2, provide preferred parking for carpool or shared-use vehicles for 5% of the total parking spaces after reductions are made from the base ratios. Preferred parking is not required if no off-street parking is provided.

Discounted Parking Rate
For projects pursuing Case 2 which will require payment for parking, a discounted parking rate of at least 20% for carpool vehicles is an acceptable substitute for preferred parking spaces."

Europe ACP added to Requirements section:
"Europe ACP: Reduced Parking Footprint
For European projects pursuing Case 2, provide preferred parking for carpool or shared-use vehicles for 5% of the total parking spaces after reductions are made from the base ratios. A discounted parking rate of at least 20% for carpool vehicles is an acceptable substitute for preferred parking spaces. The discounted rate must be publicly posted at the entrance of the parking area and permanently available to every qualifying vehicle."
Campus Applicable
No
Internationally Applicable:
No
1/11/2019Updated: 1/31/2019
Reference Guide Correction
Description of change:
Original:
"Projects with separate parking areas for visitors, employees or students must apply the proportion of preferred parking for carpools must be applied to each pool of parking."

Change to:
"Projects with separate parking areas for visitors, employees, or students must apply the proportion of preferred parking for carpools to each pool of parking."
Campus Applicable
No
Internationally Applicable:
Yes

LEEDuser expert

Marilyn Specht

LEED AP (ND, O+M), WELL AP, LFA, Fitwel Ambassador, EcoDistricts AP

SmithGroup
Senior Principal | Director of Sustainability Integration

See all LEEDuser forum discussions about this credit » Subscribe to new discussions about Hospitality-CI-v4 LTc5 View the LEED v4.1 version of this credit