Homes-v2008 Former Pilot Credit EApc71: Innovation: Performance of ENERGY STAR for Homes 1 point

LEEDuser’s viewpoint

Explore this LEED credit

Post your questions on this credit in the forum, and click on the credit language tab to review to the LEED requirements.

Credit language

USGBC logo

© Copyright U.S. Green Building Council, Inc. All rights reserved.

Intent

This prerequisite applies to projects registered prior to March 1, 2024. Projects registered after March 1, 2024 are subject to the v4 2024 Update

To improve the building’s overall energy performance and reduce its greenhouse gas emissions.

Requirements

Meet all of the following requirements:

  1. Complete all mandatory measures of ENERGY STAR for Homes version 3. Achieve a HERS Index rating that meets or exceeds the ENERGY STAR HERS Index Target (or USGBC-approved equivalent for projects outside the U.S.). Certified passive house projects automatically meet the Thermal Enclosure System section of the Rater Design Review checklist.
  2. If installed, at least one of the following appliances must be ENERGY STAR qualified (or performance equivalent for projects outside the U.S.) in each dwelling unit:
    • refrigerator;
    • dishwasher; or
    • clothes washer.
  3. All duct runs must be fully ducted (i.e., building cavities may not be used as ducts).
Existing portions of an existing building are given the following allowances: Rater Design Review Checklist 3.1. Slab insulation is strongly encouraged but not required to meet or exceed 2009 IECC levels. Rater Field Checklist 3.1. Attic insulation at the intersection of existing roof and existing exterior walls does not have to meet R-value requirements. 3.4. Advanced framing is not required on existing framed walls, 4.3. Existing sill plates on top of concrete are not required to be placed on a foam gasket. Water Management System Builder Requirements Water-Managed Site and Foundation 1.3. A capillary break under an existing slab is not required unless there are visible signs of moisture damage on the slab floor. 1.5. Exterior below-grade walls are not required to be damp-proofed on the exterior surface unless there are visible signs of moisture damage on the interior of the wall. 1.8 - Drain tiles surrounded with clean gravel and fabric filter are not required for existing slabs, unless there are visible signs of moisture damage on the slab floor 2, 3. Water-managed wall and roof assembly requirements are not required for existing walls or roofing unless there are signs of moisture damage related to vulnerabilities in the walls or roof.
Credit specific:
  • All completed inspection checklists
  • HERS Target Index, building’s HERS Index
See all forum discussions about this credit »

What does it cost?

Cost estimates for this credit

On each BD+C v4 credit, LEEDuser offers the wisdom of a team of architects, engineers, cost estimators, and LEED experts with hundreds of LEED projects between then. They analyzed the sustainable design strategies associated with each LEED credit, but also to assign actual costs to those strategies.

Our tab contains overall cost guidance, notes on what “soft costs” to expect, and a strategy-by-strategy breakdown of what to consider and what it might cost, in percentage premiums, actual costs, or both.

This information is also available in a full PDF download in The Cost of LEED v4 report.

Learn more about The Cost of LEED v4 »

Documentation toolkit

The motherlode of cheat sheets

LEEDuser’s Documentation Toolkit is loaded with calculators to help assess credit compliance, tracking spreadsheets for materials, sample templates to help guide your narratives and LEED Online submissions, and examples of actual submissions from certified LEED projects for you to check your work against. To get your plaque, start with the right toolkit.

USGBC logo

© Copyright U.S. Green Building Council, Inc. All rights reserved.

Intent

This prerequisite applies to projects registered prior to March 1, 2024. Projects registered after March 1, 2024 are subject to the v4 2024 Update

To improve the building’s overall energy performance and reduce its greenhouse gas emissions.

Requirements

Meet all of the following requirements:

  1. Complete all mandatory measures of ENERGY STAR for Homes version 3. Achieve a HERS Index rating that meets or exceeds the ENERGY STAR HERS Index Target (or USGBC-approved equivalent for projects outside the U.S.). Certified passive house projects automatically meet the Thermal Enclosure System section of the Rater Design Review checklist.
  2. If installed, at least one of the following appliances must be ENERGY STAR qualified (or performance equivalent for projects outside the U.S.) in each dwelling unit:
    • refrigerator;
    • dishwasher; or
    • clothes washer.
  3. All duct runs must be fully ducted (i.e., building cavities may not be used as ducts).
Existing portions of an existing building are given the following allowances: Rater Design Review Checklist 3.1. Slab insulation is strongly encouraged but not required to meet or exceed 2009 IECC levels. Rater Field Checklist 3.1. Attic insulation at the intersection of existing roof and existing exterior walls does not have to meet R-value requirements. 3.4. Advanced framing is not required on existing framed walls, 4.3. Existing sill plates on top of concrete are not required to be placed on a foam gasket. Water Management System Builder Requirements Water-Managed Site and Foundation 1.3. A capillary break under an existing slab is not required unless there are visible signs of moisture damage on the slab floor. 1.5. Exterior below-grade walls are not required to be damp-proofed on the exterior surface unless there are visible signs of moisture damage on the interior of the wall. 1.8 - Drain tiles surrounded with clean gravel and fabric filter are not required for existing slabs, unless there are visible signs of moisture damage on the slab floor 2, 3. Water-managed wall and roof assembly requirements are not required for existing walls or roofing unless there are signs of moisture damage related to vulnerabilities in the walls or roof.