ad-100001693

Replace the definition of "solar reflectance (SR)" with "the fraction of solar energy that is reflected by a surface on a scale of 0 to 1. Black paint has a solar reflectance of 0; white paint (titanium dioxide) has a solar reflectance of 1. The standard technique for its determination uses spectrophotometric measurements, with an integrating sphere to determine the reflectance at each wavelength. The average reflectance is then determined by an averaging process, using a standard solar spectrum, as documented by ASTM Standards E903 and E892."

ad-100001728

Replace the definition of "sedimentation" with "the addition of soil particles to water bodies by natural and human-related activities. Sedimentation often decreases water quality and can accelerate the aging process of lakes, rivers, and streams."

ad-100001727

Replace the definition of "erosion" with "a combination of processes or events by which materials of the earth's surface are loosened, dissolved, or worn away and transported by natural agents (e.g., water, wind, or gravity)"

ad-100001715

In the second paragraph, add in "optionally" before "including furniture and furnishings" so the sentence reads, "After construction and installation of all finishes (optionally including furniture and furnishings)."

ad-100001737

Replace the definition of "chain-of-custody (COC)" with "the path taken by raw materials, processed materials, and products from the forest to the consumer, including all successive stages of processing, transformation, manufacturing and distribution. A chain-of-custody certificate number on invoices for nonlabeled products indicates that the certifier's guidelines for product accounting have been followed.

ad-100001740

Replace the definition of "postconsumer material" with "waste generated by end users (households or commercial, industrial and institutional facilities) of a product no longer able to be used for its intended purpose that is recycled into raw material for a new product."

ad-100001739

In the second sentence, delete "Particularly in urban areas"; revise the last clause so that it reads, "Other sources may include vehicle exhaust, air-conditioners, and street equipment. Reduced airflow because of tall buildings and narrow streets exacerbate the effect."

100002134

Under "Group Approach" replace the sentence "All buildings in the group may be documented as one" with the following text: "Documentation may be combined provided it addresses each building individually."

100002137

Revise the Campus Approach section to read: "Eligible. For Option 1, compliance must be demonstrated for all fixtures within the LEED Campus Boundary. For Option 2, compliance may be demonstrated at the LEED Campus Boundary."

100002138

Revise the Group section to read: "Eligible. Submit separate documentation for each building. Each building in the group must have an individual whole building water meter. Each individual building in the group must meet the credit requirements for submetering of indoor plumbing fixtures and fittings, domestic hot water, and other process water. All buildings in the group can be served by the same submeter for irrigation systems, cooling towers, and reclaimed water, provided all the water used by the group is captured."