100002100

Revise Option 1, Step 2, 4th bullet with proper LM-83 section numbers (2.2.6 and 2.2.7), so reads "Include glare-control devices in the model as described in Section 2.2.6, Blinds/Shades Operation, and 2.2.7, Blinds/Shades Optical Properties."

100002101

Under Step-by-Step, Whole-House Ventilation, Step 2, delete the third bullet: "Multifamily midrise and attached single-family home projects using exhaust-only ventilation must specify how outside air is delivered to the living space at the flow rate required by ASHRAE 62.2–2010. Outside air cannot come from interior hallways or any other interior space, including adjacent units (see Further Explanation, Multifamily Ventilation Strategies). Trickle vents are a common strategy for providing make-up air.

100002098

Above the Project Type Variations section, add a Rating System Variations section that reads:
"Rating System Variations
Multifamily
For multifamily projects pursuing Option 2. Compartmentalization of smoking areas, see Further Explanation, Project Type Variations, Residential.

100002103

Add to the end of the paragraph: Multifamily buildings are allowed to exclude resident purchasing from tracking completely. If a multifamily building is mixed use, the nonresidential portions of the building must still include a minimum of 90% of the area in credit calculations.

100002104

Add to the end of the paragraph: Multifamily buildings are allowed to exclude resident purchasing from tracking completely and are encouraged to provide education to tenants about environmentally preferable purchasing and solid waste minimization.

100002105

In Step 1. add the following third bullet:
• For multifamily projects, include any unit-turnover activities, such as painting and flooring updates. Items purchased by residents may be excluded. "
In Step 5. add the following at the end of the first paragraph:
"For multifamily projects, perform these activities during unit turnover."

100002106

Under Step 1, add the following at the end of the first paragraph: "Multifamily buildings are allowed to exclude resident purchasing from tracking completely. If a multifamily building is mixed use, the nonresidential portions of the building must still include a minimum of 90% of the area in credit calculations."
Under Further Explanation, add new section: Rating System Variations
Multifamily

100002107

Under Step 1, add the following at the end of the first paragraph: "Multifamily buildings are allowed to exclude lamps purchased by residents. If a multifamily building is mixed use, the nonresidential portions of the building must still be inventoried."
Under Further Explanation add the following new section:
Rating System Variations
Multifamily

100002108

Add the following before the last sentence. "Multifamily buildings must include activities associated with unit turnover and are allowed to exclude resident purchasing from tracking completely. If a multifamily building is mixed use, the nonresidential portions of the building must still include a minimum of 90% of the area in credit calculations."
Under Rating System Variations add the following:
Multifamily

100002109

Under Rating system Variations, add the following
Multifamily
This credit requires tracking of all solid waste produced on site, including waste from residents.