ad-100000566

"No additional points are available for exemplary performance." change to "Projects that install at least 90% Energy Star labeled hard-wired fixtures should be awarded one exemplary performance point, to be counted under Innovation & Design 3."

ad-100000584

"Any tropical wood products must be identified on invoices as "FSC Pure" or "FSC Mixed"; wood products identified as "FSC Recycled" or "FSC Recycled Credit" do not meet this requirement." change to "Any tropical wood products must be FSC certified. Certification under any of the FSC labels (e.g., FSC Pure, FSC Mixed, FSC Mixed [NN]%, FSC Recycled) is acceptable."

ad-100000575

"Carpet & pad: all carpet & pad complies with Carpet & rug Institute Green Label Plus programHard flooring: automatic 1/2 point for 100% hard surface flooring.Hard flooring: additional 1/2 point for using a product that is SCS FloorScore certified." change to:Carpet & pad: 1/2 point if all carpet complies with Carpet & Rug Institute (CRI) Green Label Plus program and all pad complies with CRI Green Label program.Hard flooring: 1/2 point if 90% of the floor area is hard-surface flooring.Hard flooring: 1/2 point for using a product that is SCS FloorScore certifie

ad-100000574

[Add new paragraphs to the end of Approach & Implementation section]"This credit should only be awarded if the walls, roof, and floor are all fabricated off-site. The credit can alternatively be awarded for the use of panelized walls, roof trusses, and floor trusses throughout the home.This credit should be awarded to homes that install only pre-cut SIPs in the walls, roof, and floor.

ad-100000141

Insert the term "Sealer" in alphabetical order with the accompanying text "Sealers are coatings applied to either block materials from penetrating into or leaching out of a substrate, to prevent subsequent coatings from being absorbed by the substrate, or to prevent harm to subsequent coatings by materials in the substrate."

ad-100000136

At the end of the paragraph, insert the text "The GS-11 VOC limits applicable for this credit are summarized in Table 1. IEQc4.2 Applicable VOC Limits. "

ad-100000116

Insert the term "Tenant space" in alphabetical order with the accompanying text "Tenant space is the area within the LEED project boundary. For more information on what can and must be in the LEED project boundary see the Minimum Program Requirements (MPRs) and LEED 2009 MPR Supplemental Guidance. Note: tenant space is the same as project space."

ad-100000115

Replace the text with "Breathing zone is the region within an occupiedspace between 3 and 6 feet above the floor. Note that this definitionvaries from that of ASHRAE 62.1-2007, which states that the breathingzone is between 3 inches and 6 feet from the floor, and 2 feet from thewalls as well as fixed air conditioning equipment."

ad-100000113

Re-number the footnotes so they become the following:? CO2 monitoring is required in densely occupied spaces, in addition tooutdoor air intake flow measurement.? Project teams wishing to use ASHRAE approved addenda for thepurposes of this credit may do so at their discretion. Addenda must beapplied consistently across all LEED credits.