Revise Option 1 to read as:
Street lighting and public area lighting in the city or community should meet the efficiency related requirements of ‘ANSI/IESNA RP-8-14 Roadway Lighting or local or regional equivalent. In addition, lamps should have a minimum Luminous Efficacy of 100 lumens per watt. Points are awarded according to Table 8:

Table 8. Points awarded for efficient street lighting and public area lighting
% streetlighting and public area lighting Points
35% 1
70% 2

Revise Option 2 to read as:
Pumps in water supply, drainage and wastewater treatment must meet the requirements of the standard listed below:

Pump Energy Index listed in Table I.1 - Proposed Energy Conservation Standards for Pumps, 10 CFR Parts 429 and 431 of DOE standards Federal Register final rule Energy Conservation Program: Energy Conservation Standards for Pumps or local or national equivalent standard.

Points are awarded according to Table 9:
Table 9. Points awarded for water and wastewater
% pump capacity Points
25 % 1
50 % 2

In Option 3, change "Distributed" to "District"