In the Further Explanation > Calculations section:

1. Revise Equation 1: Percentage of energy generated purchased: insert an "or" between the words generated and purchased; and update the denominator to be "annual building site energy use in kWh" as shown below:

% energy generated or purchased = (annual quantity of renewable energy in kWh) / (annual building site energy use in kWh)

2. Revise Equation 2: Annual energy usage offset by captured bio-methane: update the denominator to be "annual building site energy use in kBtu" as shown below:

% fuel energy use offset = (annual quantity of captured bio-methane procured in kBtu) / (annual building site energy use in kBtu)

3. Replace Equation 3 as shown below.

Equation 3: Proration of Off-site renewables

Prorated Annual Renewable Percent = (Contract Term (in years) / 10 years) x Annual Renewable Energy Generation / Annual Building Site Energy Consumption

Where:
• Annual Renewable Energy Generation and Annual Building Energy Consumption use consistent units of site energy (e.g. kWh/year)
• For a one-time purchase, contract term is listed as “one year”, and annual renewable energy generation is reported as the total renewable energy generation.

Date
Updated date
Campus Applicable
Off
Internationally Applicable
Off