Date
Inquiry

Our project is a 198,000 square foot, high-rise dormitory on a university campus in an area with constant, prevailing trade winds. Due to its location, the project has provided natural ventilation for its building corridors as well as operable windows for all student apartments. In order to provide a comfortable environment for building occupants, we have undertaken a wind tunnel study, which is not typical design practice for this type of building. Two approaches were undertaken in this wind tunnel study: numerical calculations and a wind tunnel test. The numerical calculations considered input parameters such as wind speeds, wind pressure coefficients, air temperatures, opening sizes for doors and windows, and different air permeability rates for the windows, doors and cracks. The wind tunnel test was conducted by creating a 1:150 scale model of the building complex based on the drawings of the architects. The model of the planned building complex was instrumented with approximately 500 pressure taps to test for pressurization, and it was exposed to 36 different wind directions spaced 10 degrees apart (0 to 360 degrees). The building model was mounted on a turntable with a large inertial mass, allowing any wind direction to be simulated by rotating the model to the appropriate angle in the wind tunnel. The wind tunnel study resulted in a change to the project\'s natural ventilation design. It was determined that several windows needed to be moved to different fa

Ruling

The applicant has requested confirmation of a potential Innovation and Design credit for a wind-tunnel study performed during project design. Though it is commendable for a design team to apply advanced analytical techniques to push the envelope of building design, the environmental benefits attributed to the results of such an analysis are already addressed within the rating system and therefore do not qualify for additional points. The comfort of the building occupants is adequately addressed in EQ Credits 7.1 and 7.2 for naturally ventilated buildings. Other benefits are addressed under EA Credit 1, EQ Credit 2 and EQ Credit 6.2. Applicable Internationally

Internationally Applicable
On
Campus Applicable
Off
Credits