LEED reference material does not give clear guidance on how to use analysis software for documentation, and we are simply asking for general clarification regarding technical requirements. The numbers below correspond to the analysis steps in the reference manual. From EQ 8.1 Option 2-Daylight Simulation Model: 1.Regarding materials, a problem comes up when we have a core and shell project where the reflectance values of internal materials are unknown. Could there be suggested default values to use in this instance? 2.The analysis grid 30" off of the ground is reasonable but the reference manual does not describe placing an actual work plane in the analysis model. Without an actual work plane there can be instances where a floor-to-ceiling glazing allows light to bounce further into back than if the spaces were filled with furniture or desks. A recently published book on the subject states "Since Option 2 LEED-NC Version 2.2 requires 25 foot-candles of daylight in 75% of regularly occupied areas at the workplane level.the simulation models should have the workplanes incorporated." The image in this book shows a modeled workplane in the middle of the space with the caption "A model used for qualifying for the LEED daylighting credit." Nowhere in LEED literature have I found an indication that we should model the plane, though doing so will affect the results. 3."Clear sky conditions at 12:00 noon on the equinox (March 21/September 21)" is thought not to be technical enough by many experts. Perhaps LEED should cite using CIE Clear Sky as one option, or the Perez All-Weather Sky Model as another option, but with either it needs to specify how the location is defined: o If we use a CIE Clear Sky (static simulation) option we must find "design sky illuminance" values. There are many ways to find this value but we should have a clear indication of an accepted source(s. o If we use the Perez Model (static simulation) we incorporate actual weather data and our calculations are potentially more accurate. But with a static simulation we only calculate for 1 specific day and that day could be cloudy, so how could we approach this credit if we want our results based on weather data? Do we want our results based on weather data? It\'s our opinion that analysis tools are sophisticated enough that LEED should require dynamic simulations which calculate annual daylight autonomy values from weather data. 4.Item 4 proves misleading when you get to 5. 5.This allows us to include the percentage of the floor area above the threshold even if the entire room is not above, contrary to item 4. This misunderstanding has generated multiple CIRs already, none of which explain it clearly. Am I right to assume that all area above the threshold can be counted, as long as we define these areas separately? Option 3 is clearer about this issue. Item 5 also brings up a question of how to calculate the floor area from a grid of points. Some software programs do this for you but only after interpolating the values between points using contour lines. It should be explained how to derive compliant area based on point readings, and perhaps we should be warned that points falling within walls or columns will read "0" which throws off the data (your example image, Figure 2 on page 384 of LEED-NC 2.2 shows a reading of "0" for a point falls inside a column). Option 3-Daylight Measurement is also unclear about how to translate points into area, could you please be more specific?
The applicant has submitted a multi-point question regarding guidance related to the use of analysis software for the documentation of the daylight distribution. The ruling is provided in order of the questions asked. 1. While there are no specific defaults that have been established by any modeling protocols for daylight simulation, it is reasonable to assume reflectance values similar to those used for calculating lighting fixture coefficients. For example, typical reflectance values could be 50% for walls, 20% for the floor and 80% for the ceiling. If known, actual values must be used. 2. Only the analysis grid is required. There is no need to model the actual work plane. 3. While this CIR cannot provide any specific rules for selection of the sky model to be used, both methodologies are acceptable as long as the applicant submits a narrative explaining the methodology in the submittal. 4. See item 5 below 5. a. The assumption made is correct. All area above the threshold can be counted, as long as these areas separately defined. b. Software analysis from grid points is acceptable, as long as the grid points do not fall in walls, columns and other elements that may return a null value and skew results. Adjustments and additional post processing calculations may be necessary to exclude these instances. Secondly, various simulation programs draw foot-candle or daylight factor iso-contours. This is the best way to understand which areas of a space meet or exceed the threshold. Again, adjustments may be necessary. While this ruling provides guidance to the applicant, it should be noted that there are no set modeling guidelines available for daylight analysis. For the purposes of this credit, it is expected that the person(s) responsible for the analysis have enough experience to make the most appropriate determination of the daylight analysis methodology.