Do LEED v4 ND projects using earlier versions of ASHRAE Standard 90.1 comply with LEED v4 Green Infrastructure and Buildings (GIB) prerequisite Minimum building energy performance?

Ruling

Table 1. Point thresholds required for earlier ASHRAE 90.1 Appendix G models
Building Type
ASHRAE 90.1-2004 Appendix G
Minimum Performance Improvement
ASHRAE 90.1-2007 Appendix G
Minimum Performance Improvement
New Construction
Core & Shell
Major Renovation
New Construction
Core & Shell
Major Renovation
Non-residential
32%
29%
30%
28%
25%
26%
Residential (Hotels, multi-family four stories or more)
17%
14%
15%
15%
12%
13%