Hi
I'd like to know if digital media screens located outside the project building also need to comply with light pollution reduction requirements i.e do not exceed a luminance of 200 cd/m2 (nits) during nighttime hours and 2000 cd/m2 (nits) during daytime hours ?
Also should the Power consumption be included as part of "process" as it for advertising, or under Lighting (LPD) for Energy modelling ?
Michael Brown
Energy Analyst & Energy Systems Design EngineerHKS
LEEDuser Expert
9 thumbs up
July 16, 2019 - 11:31 am
There is an exemption for this type of lighting for uplight and tresspass. Will these be automatically turned off after business hours and will this project be located in LZ3 or LZ4?
Under LEEDv4 the following exterior lighting is exempt from the requirements, provided it is controlled separately from the nonexempt lighting:
Marcus Sheffer
LEED Fellow7group / Energy Opportunities
LEEDuser Expert
5909 thumbs up
July 16, 2019 - 4:52 pm
The sign lighting is exempt so it becomes a process load modeled identically in both models.
Neetika Parmar
Senior Engineer-Sustainable Development9 thumbs up
July 17, 2019 - 2:14 am
Thankyou Michael and Marcus. Its clear now.