Forum discussion

NC-v4 EAc2:Optimize energy performance

Shading by fixed construction elements - take into account for the baseline model?

Hi

Summary from Appendix G:

- self-shading is not allowed to be modeled in the baseline

- manual shading devices are not required to be modeled in the baseline

- shading from surrounding structures or terrain can be modeled, but either in baseline AND proposed the same, or not at all

- permanent shading devices such as fins, overhangs etc shall be modeled in the proposed

How to deal with permanent shading devices in the baseline?

Thanks

Sarah

 

 

0

You rely on LEEDuser. Can we rely on you?

LEEDuser is supported by our premium members, not by advertisers.

Go premium for $15.95  »

Tue, 04/16/2019 - 16:12

Just remove them from the baseline model.