NC-2009 IEQc8.1:Daylight and Views—Daylight

Open Floor Plan with different Tvis Values

Can I do prescriptive method of calculation for an open floor plan if the N+W glazing walls of the building have a Tvis of 38% and the South + East glazing walls have a Tvis of 56%?

1

You rely on LEEDuser. Can we rely on you?

LEEDuser is supported by our premium members, not by advertisers.

Go premium for $15.95  »

Thu, 04/16/2015 - 18:20

Yes. Each façade will have its own daylight zone, so for that floor you will have N,S,E,W with their own determined daylight zone and you will use the corresponding VLT. Each façade gets it own line in the calculations. I would divide the floor area appropriately for each façade.

Thu, 04/16/2015 - 18:24

Thanks Todd. I'll give that a go.