I wonder if there is a rule on how much the difference between the actual and modeled floor area can be in LEED. Thanks
You rely on LEEDuser. Can we rely on you?
LEEDuser is supported by our premium members, not by advertisers.
Go premium forForum discussion
NC-2009 EAp2: Minimum Energy Performance
I wonder if there is a rule on how much the difference between the actual and modeled floor area can be in LEED. Thanks
LEEDuser is supported by our premium members, not by advertisers.
Go premium forTo post a comment, you need to register for a LEEDuser Basic membership (free) or login to your existing profile.
A portion of our building envelope is historic. Can we exclude it from our model?
For an existing building, do I need to rotate the model?
Our process load is higher than 25%. Do we have to justify that?
Our local code references ASHRAE 90.1-2010. Should I use that for my documentation, or 90.1-2007?
Can mezzanines open to floors below be excluded from the energy model?
How do I provide a zip code for an international location?
For a project outside the U.S., how do I determine the climate zone?
For a project outside the U.S., how do I determine the Target Finder score?
Do hotel rooms need automatic light shut-off control?
How commonly are the 90.1 mandatory compliance forms submitted as part of EAp2/EAc1?
The Section 9 space-by-space method does not include residential space types. What should I use?
Can the Passive House Planning Package (PHPP) be used to energy model for LEED?
Which baseline HVAC system do I use if my building has no heating or air conditioning?
Our project has a diesel backup generator. Should we include it in our energy model?
Can SHGC be higher in the proposed than in the baseline model?
Marcus Sheffer
LEED Fellow7group / Energy Opportunities
LEEDuser Expert
5909 thumbs up
February 18, 2015 - 10:32 am
The "actual" area should be the gross area. This is what should be reported for the project.
Within EAp2 the area in the model may differ somewhat. Some software is based on the gross area so in that case the areas should be very similar. Some software uses the net area (minus exterior wall and interior partitions), in this case the difference should be no greater than 10% without a detailed explanation.
Haojie Wang
Energy ModelerKJWW Engineering
4 thumbs up
February 18, 2015 - 10:34 am
Thanks Marcus for the quick response
Francesco Passerini
engineer90 thumbs up
February 20, 2015 - 5:07 am
The area of the internal partitions shall considered for the calculation of the interior lighting power of the baseline model, as referred in the paragraph 9.6.1b of ASHRAE 90.1-2007 (“For each space enclosed by partitions 80% or greater than ceiling height, determine the gross interior floor area by measuring to the center of the partition wall.”), while I think that the external walls shall not be considered in that calculation.