Hi, we are working on a residential project. I would like to know how do we calculate the FTE and should we consider visitors and peak transients . Is there any guideline that we can follow ??
You rely on LEEDuser. Can we rely on you?
LEEDuser is supported by our premium members, not by advertisers.
Go premium for
Gwen Corrie
Sustainability StrategistGensler
November 19, 2015 - 1:36 pm
Per LEED ND v2009 (see pg 471 of Reference Guide), the term "Planned Occupancy" states, "The minimum planned occupancy for multiresidential buildings is 1 person for a studio unit, 1.5 persons for a one-bedroom unit, and 1.25 persons per bedroom for a two-bedroom or larger unit."
As for calculating visitors, we found this note someone posted for PIf3 on LEED User: "There's no hard-and-fast rule for estimating visitors. You could survey some building management companies, or you could just make an assumption such as 1 per 10 units."
Susan Di Giulio
Senior Project ManagerZinner Consultants
153 thumbs up
January 24, 2018 - 6:40 pm
On the other hand, LEED-NC v2009 Ref Guide p53 (SSc4.2) and p170 (WEp1) direct that one should assume 2 people for a 1-bedroom, 3 for a 2-bedroom, 4 for a 3-bedroom unit, etc. They don;t meantion studios, so maybe 1 occupant could be used there, to referring LEED-ND.