Could you please confirm that the 20% limit on non-motorized rights-of-way is only applicable to SLL prereq 1 Option 2 and has been removed from NPD prereq 3 and is not applicable to NPD cr 6.Option 1. Am I correct? Thank you
You rely on LEEDuser. Can we rely on you?
LEEDuser is supported by our premium members, not by advertisers.
Go premium for
Eliot Allen
LEED AP-ND, PrincipalCriterion Planners
LEEDuser Expert
303 thumbs up
August 6, 2013 - 5:37 pm
Martine, you're almost correct, except for NPDp3. The 20% cap on non-motorized ROWs was originally applied in two ways: to intersections eligible for counting toward 'connectivity' wherever that term appears, and to the types of through-connections countable on project boundaries in SLLp1 and NPDp3. A Feb 2, 2011 addenda removed the 20% cap from the 'connectivity' definition, but the 20% cap on non-motorized through-connections still remains in SLLp1 Option 2 and NPDp3 Option 1.
Eliot