Hello, Our company has a Project (in Santiago Chile) and we have a question about the additional requirement calculation for CS Core and Shell Credit 6, Green Power. The credit says that gross SF for core and shell is the complete area of the building without parking lots. So… what we need to add for usable square footage (USF)…just regularly occupied spaces or maybe another space’s? Thank You. Fernanda

0

You rely on LEEDuser. Can we rely on you?

LEEDuser is supported by our premium members, not by advertisers.

Go premium for $15.95  »

Mon, 05/06/2013 - 15:25

Usable square footage sounds like net square footage which is all of the spaces inside the building not including exterior walls, partitions, shafts, etc.

Tue, 06/23/2015 - 20:54

Hi Fernanda, According to this BOMA glossary of terms (https://goo.gl/ikupfO), the total usable area (ANSI/BOMA Z65.1-2010). is defined as occupant area plus building amenity areas. Occupants include tenants as well as owner-occupants. Building amenity areas include only those amenities that are convertible to Occupant Area and are not required by code or for the operation of the building. Shared conference rooms, exercise areas/fitness centers, child care centers, and vending areas are classified as Building Amenity Areas. The BOMA 1996 Office Floor Measurement Standard defined usable area as office area plus store area plus building common area. Usable area does not include Building Service Areas, such as building lobby and corridors; fire control center and equipment; restrooms and janitors’ closets; mechanical, electrical and communications rooms and closets; truck loading, receiving and trash; or building management and maintenance. I hope that helps.

Add new comment

To post a comment, you need to register for a LEEDuser Basic membership (free) or login to your existing profile.