FAQs about EAp2 :

For a project outside the U.S., how do I determine the Target Finder score?

Do hotel rooms need automatic light shut-off control?

How commonly are the 90.1 mandatory compliance forms submitted as part of EAp2/EAc1?

The Section 9 space-by-space method does not include residential space types. What should I use?

Can the Passive House Planning Package (PHPP) be used to energy model for LEED?

Is it acceptable to model a split-type AC with inverter technology compressor as a heat pump, like modeling VRF?

Can the Trace 700 'LEED Energy Performance Summary Report' by uploaded to LEED Online in lieu of the Section 1.4 tables spreadsheet?

A portion of our building envelope is historic. Can we exclude it from our model?

Which baseline HVAC system do I use if my building has no heating or air conditioning?

For an existing building, do I need to rotate the model?

Our project has a diesel backup generator. Should we include it in our energy model?

Our project has a large process load—75%. Despite our efforts to make an efficient HVAC design, the cost savings are minimal. What can we do to earn this prerequisite and be eligible for LEED certification? Is there any flexibility in how we model the p

Can SHGC be higher in the proposed than in the baseline model?

Our process load is higher than 25%. Do we have to justify that?

Do I need to justify the electrical and fuel rates I am using in my model?

Our local code references ASHRAE 90.1-2010. Should I use that for my documentation, or 90.1-2007?

Can I claim exterior lighting savings for canopy lighting even though a baseline model cannot include shading elements?

The project is built on a site with existing exterior lighting installed. How should this be accounted for?

Can mezzanines open to floors below be excluded from the energy model?

How do I provide a zip code for an international location?

View answers »

Forum discussion

NC-2009 EAp2:Minimum Energy Performance

NREL TP-55-46101 “Grocery Store 50% Energy Savings” document

Does anyone know if the NREL TP-55-46101 “Grocery Store 50% Energy Savings” document can be referenced in the calcs for the baseline and proposed refrigeration equipment for the NC 2009 Retail EAp2 energy model? This is for a military project, and where better to get help than LEEDuser. The next step may have to be a CIR. Thanks, John

0

You rely on LEEDuser. Can we rely on you?

LEEDuser is supported by our premium members, not by advertisers.

Go premium for $15.95  »

Thu, 12/27/2012 - 17:05

Hi John - LEED for Retail establishes baselines for refrigeration equipment.

Thu, 12/27/2012 - 17:44

Marcus, thanks. I am still wondering if this NREL guidance might qualify like an 'alternative compliance path' in leiu of the LEED Retail refrigeration requirements. The government client agency seems to have embraced this document in their design criteria, and revisions to the critieria at this tage might not be possible. Have you run into this before? John

Thu, 12/27/2012 - 17:58

It is probably a question of stringency. If the AEDG has a more stringent baseline it would likely be accepted but you would be leaving savings on the table. If the AEDG has a less stringent baseline it would likely not be accepted. Nope have not run into this.