FAQs about EAp2 :

Our project has a large process load—75%. Despite our efforts to make an efficient HVAC design, the cost savings are minimal. What can we do to earn this prerequisite and be eligible for LEED certification? Is there any flexibility in how we model the p

Can SHGC be higher in the proposed than in the baseline model?

Our process load is higher than 25%. Do we have to justify that?

Do I need to justify the electrical and fuel rates I am using in my model?

Our local code references ASHRAE 90.1-2010. Should I use that for my documentation, or 90.1-2007?

Can I claim exterior lighting savings for canopy lighting even though a baseline model cannot include shading elements?

The project is built on a site with existing exterior lighting installed. How should this be accounted for?

Can mezzanines open to floors below be excluded from the energy model?

How do I provide a zip code for an international location?

For a project outside the U.S., how do I determine the climate zone?

For a project outside the U.S., how do I determine the Target Finder score?

Do hotel rooms need automatic light shut-off control?

How commonly are the 90.1 mandatory compliance forms submitted as part of EAp2/EAc1?

The Section 9 space-by-space method does not include residential space types. What should I use?

Can the Passive House Planning Package (PHPP) be used to energy model for LEED?

Is it acceptable to model a split-type AC with inverter technology compressor as a heat pump, like modeling VRF?

Can the Trace 700 'LEED Energy Performance Summary Report' by uploaded to LEED Online in lieu of the Section 1.4 tables spreadsheet?

A portion of our building envelope is historic. Can we exclude it from our model?

Which baseline HVAC system do I use if my building has no heating or air conditioning?

For an existing building, do I need to rotate the model?

View answers »

Forum discussion

CS-2009 EAp2:Minimum Energy Performance

how i need to model that to comply with model actual equipment a

There is a fan system that will supply outdoor air for the building, This system is a big injection fan that will supply air to all zones that is completed designed and all the zones that are not completed designed (just the outdoor air had been designed), for the zones designed, there will be fan coil units. For the other zones, I don't know (Surely will be Fan coils units) As my baseline is system 8, i have modeled the proposed case in the zones completed designed easily, but for the zones that is not completed designed i have model the system fan (big injector fan) and in the interior zones the equipment as in the baseline, the diference that i have see is that my fan system have been designed just to supply outdoor air, not to be a function of cooling. So, it don't met the setpoint temperature because it need more outdoor air than my system can supply. When i use Fan coils unit it met the setpoint temperature. Another option is model a VAV system instead of my injector fan. Please, how i need to model that to comply with model actual equipment and for zones not completed designed like the baseline? Thank in advance.

0

You rely on LEEDuser. Can we rely on you?

LEEDuser is supported by our premium members, not by advertisers.

Go premium for $15.95  »

Mon, 12/03/2012 - 17:25

See Table G3.1.1-8 for information on what to model is zones without full design. Always model the proposed as designed. If not designed model identical to baseline.