NC-2009 IEQc8.1:Daylight and Views—Daylight

Airport regularly occupied space

Hello, We are working to certify a Passenger Terminal Building (PTB). One of our concern is related to IEQ 8.1 - Daylighting, the PTB contains several spaces considered as multi-occupants spaces like: - International arrivals Hall - Domestic arrivals Hall - International departure hall - International arrivals Hall - Baggage reclaim, boarding gates.. We believe that these spaces above are not regularly occupied spaces because it concern passengers only and Airport staff occupy only offices, passport control, immigration, CIP/VIP lounges. According to your experience is it correct to exclude these areas? Thanks in advance.

0

You rely on LEEDuser. Can we rely on you?

LEEDuser is supported by our premium members, not by advertisers.

Go premium for $15.95  »

Mon, 11/05/2012 - 17:46

Saliha, If you are still in design stage, I would suggest incorporating daylight in that area because typically those area in airport still require significant illuminance level (as I remember airport requires typically around 200 lux in those areas). By incorporating daylight, it will help you to reduce energy usage. If you want to exclude, in my opinion, you may still need to include check-in counters or areas where the staffs work in there and where the passangers sit. You may try to exclude other areas and assume them as corridors. Additionally narrative may be required by the reviewer if he/she doesn't agree with your exclusion.

Tue, 11/06/2012 - 13:54

Saliha, I'll second what Eddy said about incorporating daylight into those spaces first instead of trying to determine whether they will be regularly occupied or not to meet a credit requirement. According to the regular occupied space matrix dated July 2012, only ticket and agent counters and club lounges are considered regularly occupied. However, it is noted that these spaces should be designed as regularly occupied, and therefore if designed as, then would be. I would say that arrival halls, baggage claim, and boarding gates can be excluded. But departure halls would be a tough argument. I'm assuming everyone has flown and know that you are typically in departure halls areas for at least an hour, especially if you are changing flights.

Tue, 11/06/2012 - 15:50

Eddy & Todd, Thank you very much! In fact there will be daylight into those area but we dont have specific requirements for the luminance level (the project is located outside of U.S.). But the global result with DesignBuilder with all spaces is not enough to satisfy the LEED requirements. But I agree that it is more relevant to maintain departure halls as regularly occupied spaces.