FAQs about EAp2 :

Can the Passive House Planning Package (PHPP) be used to energy model for LEED?

Is it acceptable to model a split-type AC with inverter technology compressor as a heat pump, like modeling VRF?

Can the Trace 700 'LEED Energy Performance Summary Report' by uploaded to LEED Online in lieu of the Section 1.4 tables spreadsheet?

A portion of our building envelope is historic. Can we exclude it from our model?

Which baseline HVAC system do I use if my building has no heating or air conditioning?

For an existing building, do I need to rotate the model?

Our project has a diesel backup generator. Should we include it in our energy model?

Our project has a large process load—75%. Despite our efforts to make an efficient HVAC design, the cost savings are minimal. What can we do to earn this prerequisite and be eligible for LEED certification? Is there any flexibility in how we model the p

Can SHGC be higher in the proposed than in the baseline model?

Our process load is higher than 25%. Do we have to justify that?

Do I need to justify the electrical and fuel rates I am using in my model?

Our local code references ASHRAE 90.1-2010. Should I use that for my documentation, or 90.1-2007?

Can I claim exterior lighting savings for canopy lighting even though a baseline model cannot include shading elements?

The project is built on a site with existing exterior lighting installed. How should this be accounted for?

Can mezzanines open to floors below be excluded from the energy model?

How do I provide a zip code for an international location?

For a project outside the U.S., how do I determine the climate zone?

For a project outside the U.S., how do I determine the Target Finder score?

Do hotel rooms need automatic light shut-off control?

How commonly are the 90.1 mandatory compliance forms submitted as part of EAp2/EAc1?

View answers »

Forum discussion

CS-2009 EAp2:Minimum Energy Performance

EAp2-2 Section 1.3 - Advisory Messages

Hello, I am filling in my EAp2 template under LEED 2009 for Healthcare. Under Section 1.3 Advisory Messages, it says that I can find the data for this table in my Energy Pro outputs. However, neither I or my LEED fascilitator can locate this data anywhere in my Energy Model outputs. Can someone tell me where I can find the data to fill in this table? I thank you in advance for your help. All else in the template is complete and time is of the esscence. Thanks

0

You rely on LEEDuser. Can we rely on you?

LEEDuser is supported by our premium members, not by advertisers.

Go premium for $15.95  »

Wed, 09/19/2012 - 18:44

Since EnergyPro is a DOE2 product this information will be in your .sim file. The warning and errors are in the beginning and the unmet load hours are in the SS-E reports and the totals are on the BEPU and BEPS reports. If you still see hours outside throttling range multiply this percentage times 8760 to get your unmet load hours. Not sure if EnergyPro provides a report that gives you this information.

Wed, 09/19/2012 - 18:53

Thank you very much. Found the .sim file. I will peruse it to find the info.

Wed, 09/19/2012 - 19:20

It opens in Word but then requires some reformatting.