CS-2009 WEp1:Water Use Reduction

Showers for SSc4.2

Hi, I have doubts regarding showers for bicycle racks calculations for WEp1. In theory only certain group of office staff will use them, so should I create a specyfic extra group (in table WEp1-2 - fixture group definition) of FTE`s only for showers (i.e. 5% of all FTEs)? The same problem refer to toilets is shower space. Does anyone have an idea or experience what will be the best solution? Best, R.

0

You rely on LEEDuser. Can we rely on you?

LEEDuser is supported by our premium members, not by advertisers.

Go premium for $15.95  »

Wed, 09/12/2012 - 15:53

No need to create a separate fixture group for the FTE shower use in Table WEp1-2 - Fixture Group Definition. Fixture groups are meant to define different occupant groups (i.e. office, warehouse, retail, etc.) within the building that use a specific subset of flow and flush fixtures. If the project occupants have similar usage patterns, one fixture usage group should be used to represent the entire occupancy. The form will automatically calculate the daily usage rates for the plumbing fixtures entered in the Fixture Group when the group is assigned to each fixture.