Our client is occupying the 8th floor of a G+8 building. The central plant is a combination of Air cooled and water cooled chillers. The conditioned area of the project area alone is 45,000 sqft and segment area is 322,000 sqft. I simulated using the project area-segment area method. I used the existing conditions for segment area in both base case and proposed case. I modeled the project area as per ASHRAE 90.1 2007. Now the problem is with the savings calculation. As per LEED, the formula is (Base case-Proposed Case)/(Base case*(project area/segment area)). Since the project is occupying only 1 floor, the project area/ segment area ratio comes up to 0.139 and because of this the savings goes higher than 100%. In other words, we will be multiplying the savings by 7 times if we calculate the savings by the usual formula, (Base case- Proposed case)/base case. Kindly guide how to proceed. Thank you