In the reference guide for LEED NCv2009, p 556 they identify shades - see bullet 3
"If the project uses automated shades, the maximum footcandle level does not apply."
This implies that with manually operated shades the maximum level does apply - e.g. you cannot assume that they'll always be operated optimally to minimize glare. A number of studies on daylighting bear this out - most people do not change their blinds frequently, so they end up more closed than open - defeating daylight entry.
The reference guide also discusses regularly occupied spaces - I defer to others with more retail experience on corridors, but restrooms are not considered regularly occupied.
You rely on LEEDuser. Can we rely on you?
LEEDuser is supported by our premium members, not by advertisers.
What happens if we have fixed louvers on an open circulation hallway used to connect the spaces? do i need to take into account that space? it is not an interior space, it will be more as a terrace.
Hello Juan,
Are you asking if you need to include the hallway space? If so, the answer is no because it is not classified as a regularly occupied space.