You can establish compliance based on an alternative method to ASHRAE-55 by identifying an equivalent source of thermal comfort recommendations (from an industry group or a specialized ASHRAE design guide).
For spaces such as warehouses that are not normally conditioned for comfort, the project team may include one or more of the following design alternatives: radiant flooring; circulating fans; passive systems, such as nighttime air, heat venting, or wind flow; localized active cooling (refrigerant or evaporative-based systems) or heating systems; or localized, hard-wired fans that provide air movement for occupants' comfort. See LEED Interpretation #10279 for more details.