Log in
LEED v2009
New Construction
Indoor Environmental Quality
Low-Emitting Materials—Flooring Systems

LEED CREDIT

NC-2009 IEQc4.3: Low-emitting materials - flooring systems 1 point

See all forum discussions about this credit »

Credit achievement rate

XX%

Upgrade to LEEDuser Premium to see how many projects achieved this credit. Try it free »

LEEDuser expert

Brent Ehrlich

BuildingGreen
Products and materials specialist

LEEDuser’s viewpoint

Frank advice from LEED experts

LEED is changing all the time, and every project is unique. Even seasoned professionals can miss a critical detail and lose a credit or even a prerequisite at the last minute. Our expert advice guides our LEEDuser Premium members and saves you valuable time.

Credit language

USGBC logo

© Copyright U.S. Green Building Council, Inc. All rights reserved.

Requirements

Option 1
All flooring must comply with the following as applicable to the project scope:
  • All carpet installed in the building interior must meet one of the following requirements:
    • Meets the testing and product requirements of the Carpet and Rug Institute Green Label Plus1 program.
    • Maximum VOC concentrations are less than or equal to those specified in the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda, using the office scenario as defined in Table 7.5 within the practice. The additional VOC concentration limits listed in Section 9.1a must also be met.
    • Maximum VOC concentrations meet the California requirements specified above based on the following:
      • California Department of Public Health (CDPH) Standard Method V1.1-2010 using test results obtained at the 14 day time point
      • Projects outside the U.S. may use the German AgBB/DIBt testing method and all testing methods based on AgBB/DIBt method (GUT, EMICODE, Blue Angel) using test results obtained at the 3 day or 7 day or 14 day time point. For caprolactam, if test results obtained at the 3 day or 7 day time point is used, the emission concentration must be less than ½ of the concentration limit specified above because the emission may not have peaked at the measured time points. If a European testing method (AgBB/DIBt GUT, EMICODE, Blue Angel) had used parameters for calculating test results different from those specified in the referenced California method, then the European test results for carpets or floorings need to be converted into California air concentrations by multiplication with 0.7.
  • All carpet cushion installed in the building interior must meet the requirements of the Carpet and Rug Institute Green Label program.
  • All carpet adhesive must meet the requirements of IEQ Credit 4.1: Adhesives and Sealants, which includes a volatile organic compound (VOC) limit of 50 g/L (0.4 lb/gal).
  • All hard surface flooring installed in the building interior must meet one of the following requirements:
    • Meet the requirements of the FloorScore2 standard (current as of the date of this rating system, or more stringent version) as shown with testing by an independent third-party.
    • Demonstrate maximum VOC concentrations less than or equal to those specified in the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda, using the office scenario as defined in Table 7.5 within the practice.
    • Maximum VOC concentrations meet the California requirements specified above based on the following:
      • California Department of Public Health (CDPH) Standard Method V1.1-2010 using test results obtained at the 14 day time point
      • Projects outside the U.S. may use the German AgBB/DIBt testing method and all testing methods based on AgBB/DIBt method (GUT, EMICODE, Blue Angel) using test results obtained at the 3 day or 7 day or 14 day time point. For caprolactam, if test results obtained at the 3 day or 7 day time point is used, the emission concentration must be less than ½ of the concentration limit specified above because the emission may not have peaked at the measured time points. If a European testing method (AgBB/DIBt GUT, EMICODE, Blue Angel) had used parameters for calculating test results different from those specified in the referenced California method, then the European test results for carpets or floorings need to be converted into California air concentrations by multiplication with 0.7.
    Mineral based finish flooring products such as tile, masonry, terrazzo, and cut stone without integral organic-based coatings and sealants and unfinished/untreated solid wood flooring qualify for credit without any IAQ testing requirements. However, associated site-applied adhesives, grouts, finishes and sealers must be compliant for a mineral-based or unfinished/untreated solid wood flooring system to qualify for credit.
    • Concrete, wood, bamboo and cork floor finishes such as sealer, stain and finish must meet the requirements of South Coast Air Quality Management District SCAQMD) Rule 1113, Architectural Coatings, rules in effect on January 1, 2004.
    • Tile setting adhesives and grout must meet South Coast Air Quality Management District (SCAQMD) Rule 1168. VOC limits correspond to an effective date of July 1, 2005 and rule amendment date of January 7, 2005.
    • For carpet adhesive, concrete, wood, bamboo and cork floor finishes, and tile setting adhesives, compliance can be demonstrated with test results of:
      • Total volatiles fraction, based on one of the following, provided that water and exempt compounds are subtracted from total volatiles test results and the mass VOC content is calculated consistent with SCAQMD Rule 1113 and Rule 1168:
        • ASTM D2369
        • EPA method 24
        • ISO 11890 part 1
      • Total volatile organic compounds fraction, based on one of the following, provided that all VOCs with a boiling point up to 280°C (536°F) are included, and exempt compounds are subtracted from total volatiles test results and the mass VOC content is calculated consistent with SCAQMD Rule 1113 and Rule 1168.
        • ASTM D6886
        • ISO 11890 part 2
      1 The Green Label Plus program for carpets and its associated VOC emission criteria in micrograms per square meter per hour, along with information on testing method and sample collection developed by the Carpet and Rug Institute (CRI) in coordination with California’s Sustainable Building Task Force and the California Department of Public Health , are described in Section 9, Acceptable Emissions Testing for Carpet, DHS Standard Practice CA/DHS/EHLB/R-174, dated 07/15/04. 2 FloorScore is a voluntary, independent certification program that tests and certifies hard surface flooring and associated products for compliance with criteria adopted in California for indoor air emissions of Volatile Organic Compounds (VOCs) with potential health effects. The program uses a small-scale chamber test protocol and incorporates VOC emissions criteria, developed by the California Department of Public Health.
      OPTION 2
      All flooring elements installed in the building interior must meet the testing and product requirements of the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda. Mineral-based finish flooring products such as tile, masonry, terrazzo, and cut stone without integral organic based coatings and sealants and unfinished/untreated solid wood flooring qualify for credit without any IAQ testing requirements. However, associated site-applied adhesives, grouts, finishes and sealers must be compliant for a mineral-based or unfinished/untreated solid wood flooring system to qualify for credit.
      Credit substitution available
      You may use the LEED v4 version of this credit on v2009 projects. For more information check out this article.
See all forum discussions about this credit »

What does it cost?

Cost estimates for this credit

On each BD+C v4 credit, LEEDuser offers the wisdom of a team of architects, engineers, cost estimators, and LEED experts with hundreds of LEED projects between then. They analyzed the sustainable design strategies associated with each LEED credit, but also to assign actual costs to those strategies.

Our tab contains overall cost guidance, notes on what “soft costs” to expect, and a strategy-by-strategy breakdown of what to consider and what it might cost, in percentage premiums, actual costs, or both.

This information is also available in a full PDF download in The Cost of LEED v4 report.

Learn more about The Cost of LEED v4 »

Frequently asked questions

If I have no flooring products in the scope of my project, can I earn this credit?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

How do I handle a polished concrete floor?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

Should mineral-based finish flooring products (without any integral organic-based coatings and sealants) and unfinished/untreated solid wood flooring be documented on the IEQc4.3 LEED Online form, even though they are exempt from certification requirements?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

On a renovation, should flooring that is previously installed be subject to the credit requirements?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

One flooring adhesive we are using falls under both IEQc4.1 and IEQc4.3, and is over the VOC limit. We are using the VOC budget method to meet IEQc4.1 requirements, but are we automatically disqualifed from IEQc4.3?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

The credit requirements are allowed to exempt unfinished wood flooring from the credit requirements, but wood flooring is almost always finished. This is confusing!

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

I have an international project and my flooring products aren’t tested using any of the above standards. How can I tell if they still comply?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

See all forum discussions about this credit »

Addenda

10/1/2012Updated: 9/26/2015
Global ACP
Description of change:
Under "Carpet and Rug Institute (CRI) Green Label Plus Testing Program, replace "http://www.carpet-rug.com" with "http://www.carpet-rug.org."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The second new bullet should read: "Demonstrate maximum VOC concentrations less than or equal to those specified in the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda, using the office scenario as defined in Table 7.5 within the practice."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The second indented bullet should read: "Projects outside the U.S. may use the German AgBB/DIBt testing method and all testing methods based on AgBB/DIBt method (GUT, EMICODE, Blue Angel) using test results obtained at the 3 day or 7 day or 14 day time point. For caprolactam, if test results obtained at the 3 day or 7 day time point is used, the emission concentration must be less than 1/2 of the concentration limit specified above because the emission may not have peaked at the measured time points."
Campus Applicable
No
Internationally Applicable:
Yes
4/14/2010Updated: 2/14/2015
Rating System Correction
Description of change:
Remove the fifth bulleted item
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first indented bullet should read: "California Department of Public Health (CDPH) Standard Method V1.1-2010 using test results obtained at the 14 day time point"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add a new paragraph after the bullets that reads: "If a European testing method (AgBB/DIBt GUT, EMICODE, Blue Angel) had used parameters for calculating test results different from those specified in the referenced California method, then the European test results for carpets or floorings need to be converted into California air concentrations by multiplication with 0.7."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The fourth original bullet should read: "All hard surface flooring installed in the building interior must meet one of the following requirements:"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first new indented bullet should read: "ASTM D6886"
Campus Applicable
No
Internationally Applicable:
Yes
4/14/2010Updated: 2/14/2015
Rating System Correction
Description of change:
Replace the text of the fourth bulleted item with the following text:All hard surface flooring must meet the requirements of the FloorScore?standard (current as of the date of this rating system, or more stringentversion) as shown with testing by an independent third-party. Mineralbasedfinish flooring products such as tile, masonry, terrazzo, and cutstone without integral organic-based coatings and sealants andunfinished/untreated solid wood flooring qualify for credit without any IAQtesting requirements. However, associated site-applied adhesives, grouts,finishes and sealers must be compliant for a mineral-based orunfinished/untreated solid wood flooring system to qualify for credit.
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The third new bullet should read: "Maximum VOC concentrations meet the California requirements specified above based on the following:"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first new indented bullet should read: "ASTM D2369"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add a new bullet after the three options, indented to the same level as the bullet for "Total volatiles fraction" that reads: "Total volatile organic compounds fraction, based on one of the following, provided that all VOCs with a boiling point up to 280
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first new bullet should read: "Meets the testing and product requirements of the Carpet and Rug Institute Green Label Plus"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add a new indented bullet after the last bullet that reads: "Total volatiles fraction, based on one of the following, provided that water and exempt compounds are subtracted from total volatiles test results and the mass VOC content is calculated consistent with SCAQMD Rule 1113 and Rule 1168:"
Campus Applicable
No
Internationally Applicable:
Yes
4/14/2010Updated: 2/14/2015
Reference Guide Correction
Description of change:
At the end of the paragraph, add the following text:Mineral-based finish flooring products such as tile, masonry, terrazzo, andcut stone without integral organic-based coatings and sealants andunfinished/untreated solid wood flooring qualify for credit without any IAQtesting requirements. However, associated site-applied adhesives, grouts,finishes and sealers must be compliant for a mineral-based orunfinished/untreated solid wood flooring system to qualify for credit.
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The second new indented bullet should read: "EPA method 24"
Campus Applicable
No
Internationally Applicable:
Yes
10/1/2012Updated: 2/14/2015
Global ACP
Description of change:
Replace the definition of "volatile organic compounds (VOC's)" with "a carbon compound that vaporizes (becomes a gas) at normal room temperatures. VOCs contribute to air pollution directly and through atmospheric photochemical reactions (excluding carbon monoxide, carbon dioxide, carbonic acid, metallic carbides and carbonates, and ammonium carbonate) to produce secondary air pollutants, principally ozone and peroxyacetyl nitrate."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The third new bullet should read: "Maximum VOC concentrations meet the California requirements specified above based on the following:"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add a new paragraph after the bullets that reads: "If a European testing method (AgBB/DIBt GUT, EMICODE, Blue Angel) had used parameters for calculating test results different from those specified in the referenced California method, then the European test results for carpets or floorings need to be converted into California air concentrations by multiplication with 0.7."
Campus Applicable
No
Internationally Applicable:
Yes
2/2/2011Updated: 2/14/2015
Reference Guide Correction
Description of change:
Replace text with the following:NC & SchoolsThis credit is not eligible for exemplary performance under the Innovation and Design section.CSProjects that require and enforce tenants to meet the requirements in IEQ Credit 4 (4.1, 4.2, 4.3, and 4.4) throughout the tenant space are eligible for exemplary performance under the Innovation in Design section.
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Under the first bullet, add three new bullets, indented:
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first new bullet should read: "Meet the requirements of the FloorScore standard (current as of the date of this rating system, or more stringent version) as shown with testing by an independent third-party."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Under the fourth original bullet, add three new bullets, indented:
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The second new indented bullet should read: "ISO 11890 part 2"
Campus Applicable
No
Internationally Applicable:
Yes
4/14/2010Updated: 2/14/2015
Rating System Correction
Description of change:
At the end of the paragraph, add the following text:Mineral-based finish flooring products such as tile, masonry, terrazzo, andcut stone without integral organic-based coatings and sealants andunfinished/untreated solid wood flooring qualify for credit without any IAQtesting requirements. However, associated site-applied adhesives, grouts,finishes and sealers must be compliant for a mineral-based orunfinished/untreated solid wood flooring system to qualify for credit.
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add 2 bullets below the third new bullet, indented further:
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first bullet should read: "All carpet installed in the building interior must meet one of the following requirements:"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The second indented bullet should read: "Projects outside the U.S. may use the German AgBB/DIBt testing method and all testing methods based on AgBB/DIBt method (GUT, EMICODE, Blue Angel) using test results obtained at the 3 day or 7 day or 14 day time point. For caprolactam, if test results obtained at the 3 day or 7 day time point is used, the emission concentration must be less than 1/2 of the concentration limit specified above because the emission may not have peaked at the measured time points."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add two new bullets, indented further, after the new indented bullet:
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The second new bullet should read: "Maximum VOC concentrations are less than or equal to those specified in the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda, using the office scenario as defined in Table 7.5 within the practice. The additional VOC concentration limits listed in Section 9.1a must also be met."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add three new bullets, indented further, after the new indented bullet:
Campus Applicable
No
Internationally Applicable:
Yes
4/14/2010Updated: 2/14/2015
Reference Guide Correction
Description of change:
Remove the fifth bulleted item
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The third new indented bullet should read: "ISO 11890 part 1"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add 2 bullets below the third new bullet, indented further:
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add a new bullet at the end of Option 1 that reads: "For carpet adhesive, concrete, wood, bamboo and cork floor finishes, and tile setting adhesives, compliance can be demonstrated with test results of:"
Campus Applicable
No
Internationally Applicable:
Yes
4/14/2010Updated: 2/14/2015
Reference Guide Correction
Description of change:
Replace the text of the fourth bulleted item with the following text:All hard surface flooring must meet the requirements of the FloorScore?standard (current as of the date of this rating system, or more stringentversion) as shown with testing by an independent third-party. Mineralbasedfinish flooring products such as tile, masonry, terrazzo, and cutstone without integral organic-based coatings and sealants andunfinished/untreated solid wood flooring qualify for credit without any IAQtesting requirements. However, associated site-applied adhesives, grouts,finishes and sealers must be compliant for a mineral-based orunfinished/untreated solid wood flooring system to qualify for credit.
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Delete the Alternative Compliance Path for Projects Outside the U.S.
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first indented bullet should read: "California Department of Public Health (CDPH) Standard Method V1.1-2010 using test results obtained at the 14 day time point"
Campus Applicable
No
Internationally Applicable:
Yes
1/1/2013
LEED Interpretation
Inquiry:

According to footnote 1 on the IEQc4.3 Form, "Mineral-based finish flooring products such as tile, masonry, terrazzo, and cut stone without any integral organic-based coatings and sealants and unfinished/untreated solid wood flooring qualify for credit without any IAQ testing requirements." Is it necessary to list them as a material on the form since there is no way to indicate that it is exempt from testing?

Ruling:

The project team is asking whether mineral-based finish flooring products (without any integral organic-based coatings and sealants) and unfinished/untreated solid wood flooring need to be included on the LEED IEQc4.3 (Low-Emitting Materials - Flooring Systems) Credit Form. Yes, the project team should mark the form to indicate an Alternative Compliance Path. The required narrative for the Alternative Compliance Path must include a statement that the project is applying the April 14, 2010 addenda, as well as the manufacturer and specific product description of the product claiming the exemption. Manufacturer documentation for each product claiming an exemption is NOT required. Applicable Internationally.

Campus Applicable
No
Internationally Applicable:
Yes
See all forum discussions about this credit »

Checklists

Step by step to LEED certification

LEEDuser’s checklists walk you through the key action steps you need to earn a credit, including how to avoid common pitfalls and save money.

See all forum discussions about this credit »

Documentation toolkit

The motherlode of cheat sheets

LEEDuser’s Documentation Toolkit is loaded with calculators to help assess credit compliance, tracking spreadsheets for materials, sample templates to help guide your narratives and LEED Online submissions, and examples of actual submissions from certified LEED projects for you to check your work against. To get your plaque, start with the right toolkit.

Credit achievement rate

XX%

Upgrade to LEEDuser Premium to see how many projects achieved this credit. Try it free »

LEEDuser expert

Brent Ehrlich

BuildingGreen
Products and materials specialist

Get the inside scoop

Our editors have written a detailed analysis of nearly every LEED credit, and LEEDuser premium members get full access. We’ll tell you whether the credit is easy to accomplish or better left alone, and we provide insider tips on how to document it successfully.

USGBC logo

© Copyright U.S. Green Building Council, Inc. All rights reserved.

Requirements

Option 1
All flooring must comply with the following as applicable to the project scope:
  • All carpet installed in the building interior must meet one of the following requirements:
    • Meets the testing and product requirements of the Carpet and Rug Institute Green Label Plus1 program.
    • Maximum VOC concentrations are less than or equal to those specified in the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda, using the office scenario as defined in Table 7.5 within the practice. The additional VOC concentration limits listed in Section 9.1a must also be met.
    • Maximum VOC concentrations meet the California requirements specified above based on the following:
      • California Department of Public Health (CDPH) Standard Method V1.1-2010 using test results obtained at the 14 day time point
      • Projects outside the U.S. may use the German AgBB/DIBt testing method and all testing methods based on AgBB/DIBt method (GUT, EMICODE, Blue Angel) using test results obtained at the 3 day or 7 day or 14 day time point. For caprolactam, if test results obtained at the 3 day or 7 day time point is used, the emission concentration must be less than ½ of the concentration limit specified above because the emission may not have peaked at the measured time points. If a European testing method (AgBB/DIBt GUT, EMICODE, Blue Angel) had used parameters for calculating test results different from those specified in the referenced California method, then the European test results for carpets or floorings need to be converted into California air concentrations by multiplication with 0.7.
  • All carpet cushion installed in the building interior must meet the requirements of the Carpet and Rug Institute Green Label program.
  • All carpet adhesive must meet the requirements of IEQ Credit 4.1: Adhesives and Sealants, which includes a volatile organic compound (VOC) limit of 50 g/L (0.4 lb/gal).
  • All hard surface flooring installed in the building interior must meet one of the following requirements:
    • Meet the requirements of the FloorScore2 standard (current as of the date of this rating system, or more stringent version) as shown with testing by an independent third-party.
    • Demonstrate maximum VOC concentrations less than or equal to those specified in the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda, using the office scenario as defined in Table 7.5 within the practice.
    • Maximum VOC concentrations meet the California requirements specified above based on the following:
      • California Department of Public Health (CDPH) Standard Method V1.1-2010 using test results obtained at the 14 day time point
      • Projects outside the U.S. may use the German AgBB/DIBt testing method and all testing methods based on AgBB/DIBt method (GUT, EMICODE, Blue Angel) using test results obtained at the 3 day or 7 day or 14 day time point. For caprolactam, if test results obtained at the 3 day or 7 day time point is used, the emission concentration must be less than ½ of the concentration limit specified above because the emission may not have peaked at the measured time points. If a European testing method (AgBB/DIBt GUT, EMICODE, Blue Angel) had used parameters for calculating test results different from those specified in the referenced California method, then the European test results for carpets or floorings need to be converted into California air concentrations by multiplication with 0.7.
    Mineral based finish flooring products such as tile, masonry, terrazzo, and cut stone without integral organic-based coatings and sealants and unfinished/untreated solid wood flooring qualify for credit without any IAQ testing requirements. However, associated site-applied adhesives, grouts, finishes and sealers must be compliant for a mineral-based or unfinished/untreated solid wood flooring system to qualify for credit.
    • Concrete, wood, bamboo and cork floor finishes such as sealer, stain and finish must meet the requirements of South Coast Air Quality Management District SCAQMD) Rule 1113, Architectural Coatings, rules in effect on January 1, 2004.
    • Tile setting adhesives and grout must meet South Coast Air Quality Management District (SCAQMD) Rule 1168. VOC limits correspond to an effective date of July 1, 2005 and rule amendment date of January 7, 2005.
    • For carpet adhesive, concrete, wood, bamboo and cork floor finishes, and tile setting adhesives, compliance can be demonstrated with test results of:
      • Total volatiles fraction, based on one of the following, provided that water and exempt compounds are subtracted from total volatiles test results and the mass VOC content is calculated consistent with SCAQMD Rule 1113 and Rule 1168:
        • ASTM D2369
        • EPA method 24
        • ISO 11890 part 1
      • Total volatile organic compounds fraction, based on one of the following, provided that all VOCs with a boiling point up to 280°C (536°F) are included, and exempt compounds are subtracted from total volatiles test results and the mass VOC content is calculated consistent with SCAQMD Rule 1113 and Rule 1168.
        • ASTM D6886
        • ISO 11890 part 2
      1 The Green Label Plus program for carpets and its associated VOC emission criteria in micrograms per square meter per hour, along with information on testing method and sample collection developed by the Carpet and Rug Institute (CRI) in coordination with California’s Sustainable Building Task Force and the California Department of Public Health , are described in Section 9, Acceptable Emissions Testing for Carpet, DHS Standard Practice CA/DHS/EHLB/R-174, dated 07/15/04. 2 FloorScore is a voluntary, independent certification program that tests and certifies hard surface flooring and associated products for compliance with criteria adopted in California for indoor air emissions of Volatile Organic Compounds (VOCs) with potential health effects. The program uses a small-scale chamber test protocol and incorporates VOC emissions criteria, developed by the California Department of Public Health.
      OPTION 2
      All flooring elements installed in the building interior must meet the testing and product requirements of the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda. Mineral-based finish flooring products such as tile, masonry, terrazzo, and cut stone without integral organic based coatings and sealants and unfinished/untreated solid wood flooring qualify for credit without any IAQ testing requirements. However, associated site-applied adhesives, grouts, finishes and sealers must be compliant for a mineral-based or unfinished/untreated solid wood flooring system to qualify for credit.
      Credit substitution available
      You may use the LEED v4 version of this credit on v2009 projects. For more information check out this article.

XX%

Upgrade to LEEDuser Premium to see how many projects achieved this credit. Try it free »

Got the gist of IEQc4.3 but not sure how to actually achieve it? LEEDuser gives step-by-step help. Premium members get:

  • Checklists covering all the key action steps you'll need to earn the credit.
  • Hot tips to give you shortcuts and avoid pitfalls.
  • Cost tips to assess what a credit will actually cost, and how to make it affordable.
  • Ideas for going beyond LEED with best practices.
  • All checklists organized by project phase.
  • On-the-fly suggestions of useful items from the Documentation Toolkit and Credit Language.

In the end, LEED is all about documentation. LEEDuser’s Documentation Toolkit, for premium members only, saves you time and helps you avoid mistakes with:

  • Calculators to help assess credit compliance.
  • Tracking spreadsheets for materials purchases.
  • Spreadsheets and forms to give to subs and other team members.
  • Guidance documents on arcane LEED issues.
  • Sample templates to help guide your narratives and LEED Online submissions.
  • Examples of actual submissions from certified LEED projects.

If I have no flooring products in the scope of my project, can I earn this credit?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

How do I handle a polished concrete floor?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

Should mineral-based finish flooring products (without any integral organic-based coatings and sealants) and unfinished/untreated solid wood flooring be documented on the IEQc4.3 LEED Online form, even though they are exempt from certification requirements?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

On a renovation, should flooring that is previously installed be subject to the credit requirements?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

One flooring adhesive we are using falls under both IEQc4.1 and IEQc4.3, and is over the VOC limit. We are using the VOC budget method to meet IEQc4.1 requirements, but are we automatically disqualifed from IEQc4.3?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

The credit requirements are allowed to exempt unfinished wood flooring from the credit requirements, but wood flooring is almost always finished. This is confusing!

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

I have an international project and my flooring products aren’t tested using any of the above standards. How can I tell if they still comply?

The answer to this question is available to LEEDuser premium members. Start a free trial »

(If you're already a premium member, log in here.)

10/1/2012Updated: 9/26/2015
Global ACP
Description of change:
Under "Carpet and Rug Institute (CRI) Green Label Plus Testing Program, replace "http://www.carpet-rug.com" with "http://www.carpet-rug.org."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The second new bullet should read: "Demonstrate maximum VOC concentrations less than or equal to those specified in the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda, using the office scenario as defined in Table 7.5 within the practice."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The second indented bullet should read: "Projects outside the U.S. may use the German AgBB/DIBt testing method and all testing methods based on AgBB/DIBt method (GUT, EMICODE, Blue Angel) using test results obtained at the 3 day or 7 day or 14 day time point. For caprolactam, if test results obtained at the 3 day or 7 day time point is used, the emission concentration must be less than 1/2 of the concentration limit specified above because the emission may not have peaked at the measured time points."
Campus Applicable
No
Internationally Applicable:
Yes
4/14/2010Updated: 2/14/2015
Rating System Correction
Description of change:
Remove the fifth bulleted item
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first indented bullet should read: "California Department of Public Health (CDPH) Standard Method V1.1-2010 using test results obtained at the 14 day time point"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add a new paragraph after the bullets that reads: "If a European testing method (AgBB/DIBt GUT, EMICODE, Blue Angel) had used parameters for calculating test results different from those specified in the referenced California method, then the European test results for carpets or floorings need to be converted into California air concentrations by multiplication with 0.7."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The fourth original bullet should read: "All hard surface flooring installed in the building interior must meet one of the following requirements:"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first new indented bullet should read: "ASTM D6886"
Campus Applicable
No
Internationally Applicable:
Yes
4/14/2010Updated: 2/14/2015
Rating System Correction
Description of change:
Replace the text of the fourth bulleted item with the following text:All hard surface flooring must meet the requirements of the FloorScore?standard (current as of the date of this rating system, or more stringentversion) as shown with testing by an independent third-party. Mineralbasedfinish flooring products such as tile, masonry, terrazzo, and cutstone without integral organic-based coatings and sealants andunfinished/untreated solid wood flooring qualify for credit without any IAQtesting requirements. However, associated site-applied adhesives, grouts,finishes and sealers must be compliant for a mineral-based orunfinished/untreated solid wood flooring system to qualify for credit.
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The third new bullet should read: "Maximum VOC concentrations meet the California requirements specified above based on the following:"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first new indented bullet should read: "ASTM D2369"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add a new bullet after the three options, indented to the same level as the bullet for "Total volatiles fraction" that reads: "Total volatile organic compounds fraction, based on one of the following, provided that all VOCs with a boiling point up to 280
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first new bullet should read: "Meets the testing and product requirements of the Carpet and Rug Institute Green Label Plus"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add a new indented bullet after the last bullet that reads: "Total volatiles fraction, based on one of the following, provided that water and exempt compounds are subtracted from total volatiles test results and the mass VOC content is calculated consistent with SCAQMD Rule 1113 and Rule 1168:"
Campus Applicable
No
Internationally Applicable:
Yes
4/14/2010Updated: 2/14/2015
Reference Guide Correction
Description of change:
At the end of the paragraph, add the following text:Mineral-based finish flooring products such as tile, masonry, terrazzo, andcut stone without integral organic-based coatings and sealants andunfinished/untreated solid wood flooring qualify for credit without any IAQtesting requirements. However, associated site-applied adhesives, grouts,finishes and sealers must be compliant for a mineral-based orunfinished/untreated solid wood flooring system to qualify for credit.
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The second new indented bullet should read: "EPA method 24"
Campus Applicable
No
Internationally Applicable:
Yes
10/1/2012Updated: 2/14/2015
Global ACP
Description of change:
Replace the definition of "volatile organic compounds (VOC's)" with "a carbon compound that vaporizes (becomes a gas) at normal room temperatures. VOCs contribute to air pollution directly and through atmospheric photochemical reactions (excluding carbon monoxide, carbon dioxide, carbonic acid, metallic carbides and carbonates, and ammonium carbonate) to produce secondary air pollutants, principally ozone and peroxyacetyl nitrate."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The third new bullet should read: "Maximum VOC concentrations meet the California requirements specified above based on the following:"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add a new paragraph after the bullets that reads: "If a European testing method (AgBB/DIBt GUT, EMICODE, Blue Angel) had used parameters for calculating test results different from those specified in the referenced California method, then the European test results for carpets or floorings need to be converted into California air concentrations by multiplication with 0.7."
Campus Applicable
No
Internationally Applicable:
Yes
2/2/2011Updated: 2/14/2015
Reference Guide Correction
Description of change:
Replace text with the following:NC & SchoolsThis credit is not eligible for exemplary performance under the Innovation and Design section.CSProjects that require and enforce tenants to meet the requirements in IEQ Credit 4 (4.1, 4.2, 4.3, and 4.4) throughout the tenant space are eligible for exemplary performance under the Innovation in Design section.
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Under the first bullet, add three new bullets, indented:
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first new bullet should read: "Meet the requirements of the FloorScore standard (current as of the date of this rating system, or more stringent version) as shown with testing by an independent third-party."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Under the fourth original bullet, add three new bullets, indented:
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The second new indented bullet should read: "ISO 11890 part 2"
Campus Applicable
No
Internationally Applicable:
Yes
4/14/2010Updated: 2/14/2015
Rating System Correction
Description of change:
At the end of the paragraph, add the following text:Mineral-based finish flooring products such as tile, masonry, terrazzo, andcut stone without integral organic-based coatings and sealants andunfinished/untreated solid wood flooring qualify for credit without any IAQtesting requirements. However, associated site-applied adhesives, grouts,finishes and sealers must be compliant for a mineral-based orunfinished/untreated solid wood flooring system to qualify for credit.
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add 2 bullets below the third new bullet, indented further:
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first bullet should read: "All carpet installed in the building interior must meet one of the following requirements:"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The second indented bullet should read: "Projects outside the U.S. may use the German AgBB/DIBt testing method and all testing methods based on AgBB/DIBt method (GUT, EMICODE, Blue Angel) using test results obtained at the 3 day or 7 day or 14 day time point. For caprolactam, if test results obtained at the 3 day or 7 day time point is used, the emission concentration must be less than 1/2 of the concentration limit specified above because the emission may not have peaked at the measured time points."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add two new bullets, indented further, after the new indented bullet:
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The second new bullet should read: "Maximum VOC concentrations are less than or equal to those specified in the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda, using the office scenario as defined in Table 7.5 within the practice. The additional VOC concentration limits listed in Section 9.1a must also be met."
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add three new bullets, indented further, after the new indented bullet:
Campus Applicable
No
Internationally Applicable:
Yes
4/14/2010Updated: 2/14/2015
Reference Guide Correction
Description of change:
Remove the fifth bulleted item
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The third new indented bullet should read: "ISO 11890 part 1"
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add 2 bullets below the third new bullet, indented further:
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Add a new bullet at the end of Option 1 that reads: "For carpet adhesive, concrete, wood, bamboo and cork floor finishes, and tile setting adhesives, compliance can be demonstrated with test results of:"
Campus Applicable
No
Internationally Applicable:
Yes
4/14/2010Updated: 2/14/2015
Reference Guide Correction
Description of change:
Replace the text of the fourth bulleted item with the following text:All hard surface flooring must meet the requirements of the FloorScore?standard (current as of the date of this rating system, or more stringentversion) as shown with testing by an independent third-party. Mineralbasedfinish flooring products such as tile, masonry, terrazzo, and cutstone without integral organic-based coatings and sealants andunfinished/untreated solid wood flooring qualify for credit without any IAQtesting requirements. However, associated site-applied adhesives, grouts,finishes and sealers must be compliant for a mineral-based orunfinished/untreated solid wood flooring system to qualify for credit.
Campus Applicable
No
Internationally Applicable:
No
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
Delete the Alternative Compliance Path for Projects Outside the U.S.
Campus Applicable
No
Internationally Applicable:
Yes
7/6/2012Updated: 2/14/2015
Global ACP
Description of change:
The first indented bullet should read: "California Department of Public Health (CDPH) Standard Method V1.1-2010 using test results obtained at the 14 day time point"
Campus Applicable
No
Internationally Applicable:
Yes
1/1/2013
LEED Interpretation
Inquiry:

According to footnote 1 on the IEQc4.3 Form, "Mineral-based finish flooring products such as tile, masonry, terrazzo, and cut stone without any integral organic-based coatings and sealants and unfinished/untreated solid wood flooring qualify for credit without any IAQ testing requirements." Is it necessary to list them as a material on the form since there is no way to indicate that it is exempt from testing?

Ruling:

The project team is asking whether mineral-based finish flooring products (without any integral organic-based coatings and sealants) and unfinished/untreated solid wood flooring need to be included on the LEED IEQc4.3 (Low-Emitting Materials - Flooring Systems) Credit Form. Yes, the project team should mark the form to indicate an Alternative Compliance Path. The required narrative for the Alternative Compliance Path must include a statement that the project is applying the April 14, 2010 addenda, as well as the manufacturer and specific product description of the product claiming the exemption. Manufacturer documentation for each product claiming an exemption is NOT required. Applicable Internationally.

Campus Applicable
No
Internationally Applicable:
Yes