LEED CREDIT

Homes-v2008 EAc7: Water heating 1-6 points

LEEDuser’s viewpoint

Explore this LEED credit

Post your questions on this credit in the forum, and click on the credit language tab to review to the LEED requirements.

Credit language

USGBC logo

© Copyright U.S. Green Building Council, Inc. All rights reserved.

Requirements

Prerequisites

None.

Credits

7.1 Efficient hot water distribution (2 points). Design and install an energy-efficient hot water distribution system (see Figure 1). None of the branch length requirements below apply to cold water demand loads (e.g., toilets), washing machines, or tubs without showerheads. Select one of the following designs:a. Structured plumbing system. The system must meet all of the following: i. The system must have a demand-controlled circulation loop that is insulated to at least R-4. ii. The total length of the circulation loop must be less than 40 linear feet of plumbing in one-story homes. Add 2x the ceiling height for two-story homes, and add 4x the ceiling height for three- or four-story homes. iii. Branch lines from the loop to each fixture must be ≤10 feet long and a maximum of ½-inch nominal diameter. iv. The system must be designed with a push button control in each full bathroom and the kitchen and an automatic pump shut-off.b. Central manifold distribution system. The system must meet all of the following: i. The central manifold trunk must be no more than 6 feet in length. ii. The central manifold trunk must be insulated to at least R-4. iii. No branch line from the central manifold to any fixtures may exceed 20 feet in one-story homes. Add 1x the ceiling height for two-story homes, and add 2x the ceiling height for three- or four-story homes. iv. Branch lines from the manifold must be a maximum of ½-inch nominal diameter.c. Compact design of conventional system. The system must meet all of the following: i. No branch line from the water heater to any fixtures may exceed 20 feet in one-story homes. Add 1x the ceiling height for two-story homes, and add 2x the ceiling height for three- or four-story homes. ii. Branch lines from the central header to each fixture must be a maximum of ½-inch nominal diameter.7.2 Pipe insulation (1 point). All domestic hot water piping shall have R-4 insulation. Insulation shall be properly installed on all piping elbows to adequately insulate the 90-degree bend.7.3 Efficient domestic hot water (DHW) equipment (maximum 3 points). Design and install energy-efficient water heating equipment. Select one measure from Table 1 below. See all forum discussions about this credit »

What does it cost?

Cost estimates for this credit

On each BD+C v4 credit, LEEDuser offers the wisdom of a team of architects, engineers, cost estimators, and LEED experts with hundreds of LEED projects between then. They analyzed the sustainable design strategies associated with each LEED credit, but also to assign actual costs to those strategies.

Our tab contains overall cost guidance, notes on what “soft costs” to expect, and a strategy-by-strategy breakdown of what to consider and what it might cost, in percentage premiums, actual costs, or both.

This information is also available in a full PDF download in The Cost of LEED v4 report.

Learn more about The Cost of LEED v4 »

Documentation toolkit

The motherlode of cheat sheets

LEEDuser’s Documentation Toolkit is loaded with calculators to help assess credit compliance, tracking spreadsheets for materials, sample templates to help guide your narratives and LEED Online submissions, and examples of actual submissions from certified LEED projects for you to check your work against. To get your plaque, start with the right toolkit.

USGBC logo

© Copyright U.S. Green Building Council, Inc. All rights reserved.

Requirements

Prerequisites

None.

Credits

7.1 Efficient hot water distribution (2 points). Design and install an energy-efficient hot water distribution system (see Figure 1). None of the branch length requirements below apply to cold water demand loads (e.g., toilets), washing machines, or tubs without showerheads. Select one of the following designs:a. Structured plumbing system. The system must meet all of the following: i. The system must have a demand-controlled circulation loop that is insulated to at least R-4. ii. The total length of the circulation loop must be less than 40 linear feet of plumbing in one-story homes. Add 2x the ceiling height for two-story homes, and add 4x the ceiling height for three- or four-story homes. iii. Branch lines from the loop to each fixture must be ≤10 feet long and a maximum of ½-inch nominal diameter. iv. The system must be designed with a push button control in each full bathroom and the kitchen and an automatic pump shut-off.b. Central manifold distribution system. The system must meet all of the following: i. The central manifold trunk must be no more than 6 feet in length. ii. The central manifold trunk must be insulated to at least R-4. iii. No branch line from the central manifold to any fixtures may exceed 20 feet in one-story homes. Add 1x the ceiling height for two-story homes, and add 2x the ceiling height for three- or four-story homes. iv. Branch lines from the manifold must be a maximum of ½-inch nominal diameter.c. Compact design of conventional system. The system must meet all of the following: i. No branch line from the water heater to any fixtures may exceed 20 feet in one-story homes. Add 1x the ceiling height for two-story homes, and add 2x the ceiling height for three- or four-story homes. ii. Branch lines from the central header to each fixture must be a maximum of ½-inch nominal diameter.7.2 Pipe insulation (1 point). All domestic hot water piping shall have R-4 insulation. Insulation shall be properly installed on all piping elbows to adequately insulate the 90-degree bend.7.3 Efficient domestic hot water (DHW) equipment (maximum 3 points). Design and install energy-efficient water heating equipment. Select one measure from Table 1 below.
See all LEEDuser forum discussions about this credit » Subscribe to new discussions about Homes-v2008 EAc7